Selected Sis Commands; Establishing A Network (Ethernet) Connection; Connection Timeouts; Number Of Connections - Extron electronics MPX Plus 866 A Setup Manual

Media presentation matrix switchers
Hide thumbs Also See for MPX Plus 866 A:
Table of Contents

Advertisement

Remote Control

Selected SIS Commands

The switchers have Simple Instruction Set (SIS
you can use for operation and configuration. You can run these
commands from a PC connected to any of the switcher's three
serial ports or the Ethernet port. See
for connection information.

Establishing a network (Ethernet) connection

Establish a network connection as follows:
1.
Open a TCP socket to port 23 using the switcher's IP
address.
N
The factory default IP address is 192.168.254.254.
The switcher responds with a copyright message including
the date, the name of the product, the firmware version,
the part number, and the current date/time.
N
If the switcher is not password-protected, the device is now
ready to accept SIS commands.
If the switcher is password-protected, a password
prompt appears.
2.
If the switcher is password-protected, enter the appropriate
password.
If the password is accepted, the switcher responds with
Login User or Login Administrator.
If the password is not accepted, the Password prompt
reappears.

Connection timeouts

The Ethernet link times out and disconnects after a designated
period of no communications. By default, this timeout value
is set to 5 minutes, but the value can be changed. See the
Configure port timeout SIS commands on page 4-10.
N
Extron recommends leaving the default timeout at
5 minutes and periodically issuing the Query (Q)
command to keep the connection active or disconnecting
the socket and reopening the connection when necessary.
4-2
MPX Plus 866 A • Remote Control
Refer also to the MPX Plus 866 A User's Manual at www.extron.com.
) commands that
l
,
m
, and
o
, on pages 2-5,

Number of connections

A switcher can have up to 200 simultaneous TCP connections,
including all HTTP sockets and Telnet connections. When
the connection limit is reached, the switcher accepts no new
connections until some have been closed. No error message or
indication is given that the connection limit has been reached.
To maximize performance of your switcher, the number of
connections should stay low and unnecessary open sockets
should be closed.
Verbose mode
Telnet connections to a switcher can be used to monitor
for changes that occur on the switcher, such as front panel
operations and SIS commands from other Telnet sockets or a
serial port. For a Telnet session to receive change notices from
the switcher, the Telnet session must be in verbose mode 3. See
the Set verbose mode command on page 4-10. In verbose
mode 3, the Telnet socket reports changes in messages that
resemble SIS command responses.
Host-to-switcher instructions
The switcher accepts SIS commands through either serial port.
SIS commands consist of one or more characters per command
field. They do not require any special characters to begin or
end the command character sequence. Each switcher response
to an SIS command ends with a carriage return and a line feed
]
(CR/LF =
), which signals the end of the response character
string. A string is one or more characters.
N
The table that begins on the next page is a partial list
of SIS commands. For a complete listing, refer to the
MPX Plus 866 A User's Manual.
MPX Plus 866 A • Remote Control
Refer also to the MPX Plus 866 A User's Manual at www.extron.com.
4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

N 60-796-01

Table of Contents