Saving or Recalling a Preset

The DMS switchers have 32 global memory presets.
1.
Save a preset — Press and hold the Preset button until it flashes.
Save a
2 seconds
PRESET
preset
Press and hold.
Recall a preset — Press and release the Preset button.
Recall a
PRESET
preset
Press and release.
All input and output buttons with assigned presets light red.
When a preset is saved, the configuration data at
assigned preset locations will be overwritten.
1
2
3
2.
Press and release the desired input or output button.
The button blinks red to indicate that
this preset is selected to save or recall.
The Enter button blinks
1
ENTER
red to indicate the need to
activate the save or recall.
3.
Press and release the Enter button.

Locking Out the Front Panel (Executive Mode)

To toggle the front panel lock on and off, simultaneously press and hold
the Enter button and the Esc button until the Preset and View buttons
blink twice (approximately 2 seconds).
Press and hold the Enter and
Esc buttons simultaneously to
toggle executive mode on or off.
C O N T R O L
2 seconds
ENTER
PRESET
VIEW
ESC
12
DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Front Panel Operations
PRESET
The Preset button blinks.
PRESET
The Preset button lights.
INPUTS
4
5
6
15
16
C O N T R O L
ENTER
PRESET
VIEW
ESC
The Preset and View buttons
blink twice to indicate the
mode change.
Release the buttons.

Remote Control

This section describes using the remote control features of the
DMS matrix switchers to control the devices. Topics that are covered
include:

Selected SIS Commands

Installing and Starting the Control Program
Accessing the HTML Pages
Selected SIS Commands
You can use Simple Instruction Set (SIS) commands for operation and
configuration of the switchers. You can run these commands from a PC
connected to a serial port
page 8), or USB port
(item

Establishing a Network (Ethernet) Connection

The first time you connect to the switcher via the LAN port,
NOTE:
you may need to change the default settings (IP address, subnet
mask, and [optional] administrator password) of the switcher.
Establish a network connection as follows:
1.
Open a TCP socket to port 23 using the IP address of the switcher.
NOTE:
The factory default IP address is 192.168.254.254.
The switcher responds with a copyright message including the name,
firmware version, and part number of the product, and the current
date and time.
NOTES:
If the switcher is not password-protected, the device is now
ready to accept SIS commands.
If the switcher is password-protected, a password prompt
appears.
2.
If necessary, enter the appropriate password.
If the password is accepted, the switcher responds with Login User
or Login Administrator .
If the password is not accepted, the Password prompt reappears.