Pin Connector - Brady Bradyprinter THT 200M-e User Manual

Table of Contents

Advertisement

3DUDOOHO 'DWD 3RUW
A standard 36-pin parallel connector is available at the rear of the printer
for connection to the data source. Under normal circumstances, data sent
from the printer to the host computer in response to a "Printer Status
Request" command is sent through the RS-232 serial port. However, if the
host computer has a properly configured IEEE-1284 parallel port that is
recognized by the printer, status information is returned through the
parallel port. Port selection for status information is determined each time
the printer is turned on.
Parallel Port Interconnections
Table 4 shows the pin configuration and function of a standard
computer-to-printer parallel cable.

36-pin Connector

16 & 17
33 & 34
102
All manuals and user guides at all-guides.com
Table 4
1
nStrobe/HostClk
2-9
Data Bits 1-8
10
nACK/PtrClk
11
Busy/PtrBusy
12
PError/ACKDataReq
13
Select/Xflag
14
nAutoFd/HostBusy
15
Not used
Ground
18
+5V @ 750mA
19-30
Ground
31
ninit
32
nFault/NDataAvail
Not used
35
+5V through a 1.8K
36
NSelectin/1284 active