Delta Electronics AC Motor Drive VFD-G User Manual page 133

Vfd-g series specific ac motor drives for plastic molding and air compressors machinery
Table of Contents

Advertisement

Chapter 4 Parameters|
Content
Status monitor
Read only
4-82
Address
2100H
Fault code:
00: No error occurred
01: Over-current (oc)
02: Over-voltage (ov)
03: Overheat (oH)
04: Overload (oL)
05: Overload1 (oL1)
06: External fault (EF)
07: IGBT short circuit protection (occ)
08: CPU failure (cF3)
09: Hardware protection failure (HPF)
10: Current exceeds 2 times rated current during accel (ocA)
11: Current exceeds 2 times rated current during decel (ocd)
12: Current exceeds 2 times rated current during steady
state operation (ocn)
13: Ground Fault (GFF)
14: Low voltage (Lv)
15: CPU failure 1 (cF1)
16: CPU failure 2 (cF2)
17: Base Block (bb)
18: Overload (oL2)
19: Auto accel/decel failure (cFA)
20: Software protection enabled (codE)
21: EF1 Emergency stop
22: PHL (Phase-Loss)
23: Lc (Low-current)
24: FbL(Feedback Loss)
25: Reserved
26: Fan Power Fault (FANP)
27: Fan 1 Fault (FF1)
28: Fan 2 Fault (FF2)
29: Fan 3 Fault (FF3)
30: Fan 1, 2, 3 Fault (FF123)
31: Fan 1, 2 Fault (FF12)
32: Fan 1, 3 Fault (FF13)
33: Fan 2, 3 Fault (FF23)
34: Gate Drive Low Voltage Protect (Fv)
Function