Technical Description Of The Burner; Models Available; Technical Data; Overall Dimensions - Riello RDB 3.2 BX 32/50 Installation, Use And Maintenance Instructions

Kerosene burner
Hide thumbs Also See for RDB 3.2 BX 32/50:
Table of Contents

Advertisement

Available languages

Available languages

4

Technical description of the burner

4.1

Models available

Designation
RDB 3.2 BX 32/50
4.2

Technical data

Model
Delivery
(1)
Thermal output
(1)
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Protection level
Net weight
Reference conditions: Ambient temperature 20°C - Barometric pressure 1013 mbar - Altitude 0m a.s.l.
(1)
(H i = 11.86 kWh/kg)
4.3

Overall dimensions

1 8 9
1 4 0
1 6 8
Technical description of the burner
Voltage
1/230V/50Hz
1 6 4
1 6 8
9
GB
RDB 3.2 BX 32/50
2.7 - 4.2 kg/h
32 - 50 kW

Kerosene, viscosity 1.6
6 mm
~
Single-phase
50Hz 230V ± 10%
Intensity 0.6 A – Output 150 W
Speed 2800 tr/min. - 294 rad/s
5 F
Secondary 18 kV – 25 mA
Pressure; 8
15 bar
0.16 kW
IP 20
12.2 kg
1 4 5 . 5
20149460
Code
20145385
2
/s at 20°C
Tab. A
2 5 6
Fig. 1
20151139