UTC F&S RAS1156.V01
0-EXIT, Menu:
1-Card Beep
0-EXIT, Menu:
2-Buzzer
0-Exit, Menu:
3-RTE (Egress)
0-Exit, Menu:
4-Last Card
0-Exit, Menu:
5-Factory Defaults
0-Exit, Menu:
EN: Installation Sheet
Mounting the unit
1.
Remove the Allen screw from the reader mounting plate to
open the reader (Figure 5).
2.
Use the mounting plate as a template to mark the screw
holes locations on the wall.
3.
Run the cable through the rubber gasket (gasket is used
for outdoors installation) and then through the hole in the
mounting plate.
4.
Fasten the mounting plate to the wall.
5.
Connect the cable to the terminal block (Figure 2).
6.
Set the RAS address DIP switch (Figure 6).
7.
Ensure that the jumper position for the heater is On for
outdoors installation, and Off for indoors (Figure 2).
8.
Slide the reader onto the mounting plate and close the unit
with the Allen screw (reverse order of Figure 5, and then
follow Figure 7).
Connecting control panel to keypad
Refer to the ATS control panel installation guide for
instructions. Each reader has a cover tamper.
Note:
Figures and instructions also apply to the ATS1151
unless stated otherwise.
Reader connection to the ATS panels
Description
Connection
12V Power supply
P/N 466-2512 (ML) • REV C • ISS 11JUN19
Card Beep Enabled
*-Change, #-Exit
Buzzer Enabled
*-Change, #-Exit
RTE Disabled
*-Change, #-Exit
00,00,00,00,00,00
#-Exit
Set Factory Defaults?
*-Yes, #-No
ATS1151 /
Control
ATS125x
ATS1156
panel
Comms
Comms
Power
12 V
12 V
Description
0V Connection to reader
Data + connection to reader
Data − connection to reader
Request to exit button
Open collector output 50mA max.
Safety instructions
Always observe the safety regulations applicable in your
country. Read the following safety instructions before
attempting to install the product.
Before disassembling the product, disconnect the power
supply unit from the controller.
Only connect the mains to the power supply unit when all
installation procedures have been completed.
Never cover the power supply unit as it may overheat.
When installing, do not force any parts or screws.
Extra notes for installing a keypad outdoors
See Figure 4.
Install a rain protection hood over the reader.
Mount the rubber gasket (supplied) between the unit and
the wall to seal the unit.
Set the jumper J4 (Figure 2) to the On position to enable
the heater.
If a motorised lock or gate is used, mount the reader a few
metres away from the door so the lock or gate has enough
space to open fully.
Cable entry and connections
See Figure 2.
(1) Buzzer
(2) Term link
(3) Terminal block
(4) Heater jumper
(5) RAS DIP switches
Connections terminals
IN: A request to exit button (normally open, momentary
push-button switch) can be connected across "IN" and "−".
When pressed, this button controls the request to exit
function.
OUT: Open collector output, 50 mA maximum. It is the first
output of the output control group that is assigned to this
arming station.
D−, D+: Data positive and data negative connection of the
databus. Remote units can be up to 1.5 km from the ATS
control panel.
GND, PWR: Power supply. If the distance between the
arming station and the control panel does not exceed
100 m, then the arming station can be powered using the
ATS1151 /
Control
ATS125x
ATS1156
panel
GND
0V
0V
D+
D+
D+
D−
D−
D−
IN
OUT
3 / 22