Immediate Regeneration; To Advance Regeneration Cycles; To Cancel A Regeneration; Second Delayed Regeneration - Pentair EVOLIO 255 740 Installer Manual

Table of Contents

Advertisement

Info
To cancel: press
7.2.2

Immediate regeneration

1. Press and hold
ð A solid regeneration icon will be displayed.
ð Camshaft starts rotating to cycle C1.
7.2.3

To advance regeneration cycles

1. Simultaneously press
ð An hourglass will display while the camshaft is moving.
ð When the camshaft reaches next cycle, "C2" will be displayed.
2. Repeat
and
7.2.4

To cancel a regeneration

1. Press and hold
ð Hourglass will flash once cancelled.
ð Camshaft will move to service position – may take 1 to 2 minutes.
7.2.5

Second delayed regeneration

1. When a regeneration is already on going, press
be planned.
ð A "x2" icon will be flashing on the screen.
7.2.6

Second immediate regeneration

1. When a regeneration is already on going, press and hold
immediate regeneration to be planned.
ð A solid "x2" icon will be displayed on the screen.
7.3

Operation during a power failure

• All the program settings are stored in a permanent memory (NOVRAM);
• current valve position, cycle step time elapsed, and time of day are stored during a power
failure, and will be restored upon power restoration;
• time of day/day of week is kept during a power outage thanks to a supercapacitor as long as
the power is restored within 8 hours and the supercapacitor was fully charged. Multiple
power shutdown in a short period may decrease the supercapacitor charge;
• the time of day on the main display screen will flash for 5 minutes when there has been a
power failure. The flashing of the time of day can be stopped by pressing any button on the
display;
Ref. MKT-IM-037 / D - 25.10.2021
again. The regen symbol disappears.
for 5 seconds to initiate immediate manual regeneration.
and
to advance to the next cycle.
to advance through each cycle.
and
for 5 seconds to cancel the regen.
Installer manual Evolio 255 740-760 - Operation
once for a second delayed regeneration to
for 5 seconds for a second
55 / 90