Estimated Capacity; Hardness - Pentair EVOLIO 255 740 Installer Manual

Table of Contents

Advertisement

Installer manual Evolio 255 740-760 - Programming
Salt setting
L
S
H
1. Press
.
ð Setting flashes.
2. Adjust displayed settings with
3. Press
to validate the selection and advance to the
next parameter using
5.4.7

Estimated capacity

Info
The system capacity is displayed in kilograms equivalent CaCO
before a regeneration is necessary when programmed in metric units mode.
Value is derived from the system's resin volume input and salt amount input and must
be fine tuned for optimal operation.
Set the estimated capacity, in kg as CaCO
Salt setting
L
S
H
1. Press
.
ð The amount number flashes.
2. Adjust displayed capacity with
3. Press
to validate the selection and advance to the
next parameter using
5.4.8

Hardness

Set water hardness to treat at installation site in mg/L as CaCO3. Program the value of inlet
hardness taken away from expected residual hardness. For example, if inlet hardness is 300 mg/L
as CaCO
and residual hardness is set to 100 mg/L as CaCO
3
44 / 90
Evolio 255 10
Evolio 255 15
45.0
91.0
180.0
and
or
.
, following the following table.
3
Evolio 255 10
Evolio 255 15
0.3
0.5
0.7
and
or
.
Evolio 255 20
46.7
55.0
133.3
160.0
226.7
250.0
.
Evolio 255 20
0.5
0.7
0.9
1.4
1.2
1.6
.
, set 300-100=200 mg/L as CaCO
3
Ref. MKT-IM-037 / D - 25.10.2021
Evolio 255 30
53.3
136.7
226.7
of hardness removed
3
Evolio 255 30
1.0
1.9
2.3
.
3