Transport; Material; Hygiene And Sanitization; Sanitary Issues - Pentair EVOLIO 255 740 Installer Manual

Table of Contents

Advertisement

2.3.2

Transport

The following points must be observed to ensure proper operation of the system:
• do not lay down or flip over the softener at any time. The media may paste to the upper
distributor thus obstructing its slots or enter the valve and may therefore compromise the
softener operation;
• pay attention not to hit the softener;
• use all the safety lifting systems to move the softener;
• do not lift the softener by the valve or bypass.
2.3.3

Material

The following points must be observed to ensure proper operation of the system and the safety of
user:
• do not remove the locking bar while system is pressurized;
• beware of high voltages present on the transformer (220 – 230 VAC);
• do not put your fingers in the system (risk of injuries with moving parts and shock due to
electric voltage).
2.4

Hygiene and sanitization

2.4.1

Sanitary issues

Preliminary checks and storage
• Check that the brine tank and the brine well are clean and free from burr, debris or any
scraps;
• Check the integrity of the packaging. Check that there is no damage and no signs of contact
with liquid to make sure that no external contamination occurred;
• the packaging has a protective function and must be removed just before installation. For
transportation and storage, appropriate measures should be adopted to prevent the
contamination of materials or the objects themselves.
Assembly
• Assemble only with components which are in accordance with drinking water standards;
• after installation and before use, perform one or more manual regenerations in order to
clean the media bed. During such operations, do not use the water for human consumption.
Perform a disinfection of the system in the case of installations for treatment of drinking
water for human use.
Info
This operation must be repeated in the case of ordinary and extraordinary
maintenance.
It should also be repeated whenever the system remains idle for a significant time.
Ref. MKT-IM-037 / D - 25.10.2021
Installer manual Evolio 255 740-760 - Safety
13 / 90