Overflow Line Connection - Pentair EVOLIO 255 740 Installer Manual

Table of Contents

Advertisement

4.5.8

Overflow line connection

In the event of a malfunction, the brine tank overflow fitting will direct "overflow" to the drain
instead of spilling on the floor. This fitting is at the back of the cabinet.
To connect the overflow line, locate the barbed elbow at the back of the cabinet and connect a ½"
tubing (not supplied) from the elbow to the drain.
Do not elevate overflow higher than overflow fitting.
Do not tie into drain line of softener. Overflow line must be a direct, separate line from overflow
fitting to drain, sewer or tub. Allow an air gap as per drain line instructions.
Caution - material
Risk of flooding due to lack of floor drain !
Floor drain is always recommended to avoid flooding in case of overflow.
Ref. MKT-IM-037 / D - 25.10.2021
Installer manual Evolio 255 740-760 - Installation
Overflow fitting
Drain tubing
Secure hose in place
Air gap
Drain
35 / 90