Endress+Hauser Fieldbus Prosonic M FMU40 Operating Instructions Manual

Endress+Hauser Fieldbus Prosonic M FMU40 Operating Instructions Manual

Ultrasonic level measurement
Hide thumbs Also See for Fieldbus Prosonic M FMU40:
Table of Contents

Advertisement

Operating Instructions
Prosonic M FMU40/41/42/43/44
Ultrasonic Level Measurement
9
BA239F/00/en/01.09
71089089
Valid as of software version:
V 01.04

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Fieldbus Prosonic M FMU40

  • Page 1 Operating Instructions Prosonic M FMU40/41/42/43/44 Ultrasonic Level Measurement BA239F/00/en/01.09 71089089 Valid as of software version: V 01.04...
  • Page 2 You can find an overview of all the device functions in the Appendix. You can find a detailed description of all the device functions in the operating instructions BA 240F/00/en "Prosonic M - Description of Instrument Functions". This is located on the supplied documentation CD-ROM. Endress+Hauser...
  • Page 3: Table Of Contents

    Installation conditions ..... . 20 8.10 Contact addresses of Endress+Hauser ... 82 Measuring range .
  • Page 4: Safety Instructions

    Operating Manual. Strict compliance with the installation instructions and ratings as stated in this supplementary documentation is mandatory. • Ensure that all personnel are suitably qualified. • Observe the specifications in the certificate as well as national and local standards and regulations. Endress+Hauser...
  • Page 5: Notes On Safety Conventions And Symbols

    A connection made to the plant grounding system which may be of type e.g. neutral star or equipotential line according to national or company practice Temperature resistance of the connection cables t >85°C States, that the connection cables must be resistant to a temperature of at least 85 °C. Endress+Hauser...
  • Page 6: Identification

    Identification Prosonic M - FOUNDATION Fieldbus Identification Nameplate ENDRESS+HAUSER Made in Germany PROSONIC-M D-79689 Maulburg Order Code: Ser.-No.: IP68 / NEMA 6P Profibus PA Foundation Fieldbus 90 … 253 V AC 4VA 10,5 …32 V DC 1W 14 … 36 V DC 0,8W 4 …...
  • Page 7: Product Structure Fmu 40

    D Aluminium T12 housing coated to IP 68; with separate terminal compartment; with overvoltage protection Special version Screw union/entry M20x1.5 screw union G 1/2“ entry NPT 1/2“ entry M12 PROFIBUS-PA plug-in connector 7/8" FF plug Special version FMU 40 - Product designation Endress+Hauser...
  • Page 8: Product Structure Fmu 41

    D Aluminium T12 housing coated to IP 68; with separate terminal compartment; with overvoltage protection Special version Screw union/entry M20x1.5 screw union G 1/2“ entry NPT 1/2“ entry M12 PROFIBUS-PA plug-in connector 7/8" FF plug Special version FMU 41 - Product designation Endress+Hauser...
  • Page 9: Product Structure Fmu 42

    C Aluminium T12 housing coated to IP 68, with separate terminal compartment D Aluminium T 12 housing coated to IP 68, with separate terminal compartment; with overvoltage protection Special version Gland/Entry M20x1.5 gland G 1/2“ entry NPT 1/2“ entry M12 PROFIBUS-PA plug 7/8" FF plug Special version Endress+Hauser...
  • Page 10 Identification Prosonic M - FOUNDATION Fieldbus Sealing Sensor/Flange VITON flat sealing EPDM flat sealing special version Additional options A Additional options not selected FMU 42 - Product designation Endress+Hauser...
  • Page 11: Product Structure Fmu 43

    Prepared for remote display FHX 40 Special version Housing A Aluminium F12 housing coated to IP 68 Special version Screw union/entry M20x1.5 screw union G 1/2“ entry NPT 1/2“ entry M12 PROFIBUS-PA plug-in connector 7/8" FF plug Special version FMU 43 - Product designation Endress+Hauser...
  • Page 12: Product Structure Fmu 44

    H 4-wire 10.5-32VDC; 4-20mA HART Special version, to be specified Operation w/o display, via communication 4-line display VU331, Envelope curve display on site Prepared for FHX40, Remote display (accessory) Special version, to be specified FMU 44 - product designation, part 1 Endress+Hauser...
  • Page 13 Thread NPT 1/2 Plug M12 Plug 7/8“ Special version, to be specified Process Sealing Sensor/ Flange Viton EPDM Special version, to be specified Additional option A Basic version Y Special version, to be specified FMU 44 - complete product designation Endress+Hauser...
  • Page 14: Scope Of Delivery

    The device complies with the applicable standards and regulations as listed in the EC declaration of conformity and thus complies with the statutory requirements of the EC directives. Endress+Hauser confirms the successful testing of the device by affixing to it the CE mark.
  • Page 15: Installation

    Installation Installation Design; dimensions 3.1.1 FMU40, FMU41 (2.6) (3.1) 32 (1.3) ( 3.4) (2.6) (3.1) (3.7) (2.7) ENDRESS+HAUSER ENDRESS+HAUSER Prosonic M Prosonic M (3.3) (3.3) FMU 40 FMU 41 SW (AF) 60 SW (AF) 60 G1½” G2” 1½ NPT 2 NPT Ø...
  • Page 16 119 (4.7) (3.9) L00-FMU4xxxx-06-00-00-yy-008 Dimensions in mm (inch) 3.1.4 FMU43 (2.6) (3.1) (3.4) ENDRESS+HAUSER Prosonic M 2 x M8 85 (3.3) ANSI 4” DN 100 * Ø 230 (9.1) L00-FMU4xxxx-06-00-00-yy-009 Abb. 2: Dimensions in mm (inch); A: with slip-on flange; B: with mounting bracket 3.1.5...
  • Page 17 (9,50") (11,22") (0,91") 8" 150 lbs 298,5 mm 298,5 mm 342,9 mm 22, 5 mm 45° (11,75") (11,75") (13,50") (0,89") DN200 PN16 / 10 K 200 290 mm 295 mm 340 mm 23 mm 30° (11,42") (11,61") (13,39") (0,91") Endress+Hauser...
  • Page 18: Installation Variants

    Sealing ring (EPDM) supplied counter nut (PC) supplied for G 1½” and G 2” instruments Installation with installation bracket Installation with adapter flange ENDRESS+HAUSER Prosonic M Sealing ring (EPDM) adapter flange supplied sensor nozzle L00-FMU4xxxx-17-00-00-en-002 For installation bracket or adapter flange s. chapter "Accessories".
  • Page 19 Installation variants FMU42, FMU44 Installation with mounting bracket Installation with universal flange e.g. Zone 20 Zone 20 L00-FMU42xxxx-17-00-00-en-001 3.2.3 Installation variants FMU 43 Installation with Installation with universal slip-on flange (option) mounting bracket slip-on flange sensor nozzle e.g.Zone 20 Zone 20 L00-FMU43xxxx-17-00-00-en-001 Endress+Hauser...
  • Page 20: Installation Conditions

    15 m 0.79 m FMU44 11 ° 20 m 1.93 m 3.3.2 Installation in narrow shafts In narrow shafts with strong interference ENDRESS+HAUSER ENDRESS+HAUSER ENDRESS+HAUSER ENDRESS+HAUSER Prosonic M Prosonic M Prosonic M Prosonic M echoes, we recommend using an ultrasound guide pipe (e.g.
  • Page 21 • Keep to the installation distance of the channel or weir. • You can enter the "Flow to Level" linearisation curve ("Q/h curve") using ToF Tool or manually via the on-site display. Example: Khafagi-Venturi flume inflow outflow Khafagi - Venturi - flume direction of flow 1 x b L00-FMU4xxxx-17-00-00-en-003 Endress+Hauser...
  • Page 22 Installation Prosonic M - FOUNDATION Fieldbus Example: Triangular weir min. 2 H α (= full calibr.) min. 2 H min. 3 H L00-FMU4xxxx-17-00-00-en-012 Endress+Hauser...
  • Page 23: Measuring Range

    DN200/8" DN250/10" DN300/12" Emitting angle α 11° 11° 9° 6° 11° Blocking distance [m] 0,25 0,35 Max. range [m] in liquids Max. range [m] in solids " Caution! If the blocking distance is undershot, it may cause device malfunction. Endress+Hauser...
  • Page 24 The sensor range is dependent on the measuring conditions. Refer to Technical Information TI 365F/00/en for an estimation. The maximum range is shown in the above diagram (valid for good conditions). Sensor maximum range FMU40 FMU41 FMU42 10 m FMU43 15 m FMU44 20 m Endress+Hauser...
  • Page 25: Installation Hint For Fmu 40/41

    • If available: Are the measuring point number and labelling correct (visual inspection)? • Is the measuring device sufficiently protected against precipitation and direct sunlight? • Are the cable glands tightened correctly? • After aligning the housing, check the process seal at the nozzle or flange. Endress+Hauser...
  • Page 26: Wiring

    (see below). Re-insert terminal module (4). Tighten cable gland (6). 10. Tighten screws on cover plate (3). 11. Insert display (2) if fitted. 12. Screw on housing cover (1). 13. Switch on power supply. 1 2 3 4 L00-FMU4xxxx-04-00-00-yy-008 Endress+Hauser...
  • Page 27 (4) within the connection room. Make connection according to the terminal assignment (see below). Tighten cable gland (3). Screw on housing cover (1). Switch on power supply. 1 2 3 4 L00-FMU4xxxx-04-00-00-yy-009 4.1.3 Terminal assignment plant ground – L00-FMxxxxxx-04-00-00-en-013 Endress+Hauser...
  • Page 28: Wiring With Foundation Fieldbus Plug

    The following values are the voltages across the terminals directly at the instrument: Type minimum terminal maximum terminal voltage voltage standard 32 V EEx ia (FISCO model 17,5 V EEx ia (Entity concept) 24 V The current consumption is approx. 15 mA for the range of voltages given above. Endress+Hauser...
  • Page 29: Recommended Connection

    • Are the terminals correctly assigned? • Is the cable gland tight? • If available: Is the Foundation Fieldbus connector screwed tight? • Is the housing cover fully screwed on? • If power supply available: Does a display appear on the display module? Endress+Hauser...
  • Page 30: Operation

    This chapter contains the following sections: • 5.1 Operating options • 5.2 Operation with the display and operating module VU331 • 5.3 Operation with an Endress+Hauser operating software • 5.4 Operation with a FOUNDATION Fieldbus configuration software • 5.5 Operation with the handheld terminal DXR375/FC375...
  • Page 31 On-site operation Options for on-site operation • Display and operating module VU331 • Endress+Hauser operating software ("ToF Tool - FieldTool Package" or "FieldCare") Parameter access by on-site operation The following parameters can be accessed by on-site operation: • Parameters of the device specific blocks (Sensor Block, Diagnostic Block, Display Block) •...
  • Page 32: Operation With The Display And Operating Module Vu331

    L00-FMxxxxxx-07-00-00-en-002 In the measured value display, the bargraph corresponds to the output. The bargraph is segmented in 10 bars. Each completely filled bar represents a change of 10% of the adjusted span. Endress+Hauser...
  • Page 33 Contrast settings of the LCD Hardware lock / unlock After a hardware lock, an operation of the instrument via display or communication is not possible! The hardware can only be unlocked via the display. An unlock parameter must be entered to do so. Endress+Hauser...
  • Page 34 The third digit numbers the individual functions within the function group: → • tank shape • basic setup • medium property • process cond..Hereafter the position is always given in brackets (e.g. "tank shape" (002)) after the described function. Endress+Hauser...
  • Page 35 Press F to select the next function. Press O and S (= Q) once; return to previous function. Press O and S (= Q) twice; return to Group Selection. Press O and S (= Q) to return to Measured value display. Endress+Hauser...
  • Page 36 ToF Tool – Fieldtool Package The ToF Tool is a graphic and menu-guided operating program for measuring devices from Endress+Hauser. It is used for the commissioning, data storage, signal analysis and documentation of the devices. The following operating systems are supported: WinNT4.0, Win2000 and Windows XP.
  • Page 37 FieldCare FieldCare is an Endress+Hauser asset management tool based on FDT technology. With FieldCare, you can configure all Endress+Hauser devices as well as devices from other manufacturers that support the FDT standard. The following operating systems are supported: WinNT4.0, Win2000 and Windows XP.
  • Page 38 Operation Prosonic M - FOUNDATION Fieldbus Menu-guided commissioning MicropilotM-en-305 Signal analysis via envelope curve MicropilotM-en-306 Endress+Hauser...
  • Page 39 Prosonic M - FOUNDATION Fieldbus Operation Tank linearisation MicropilotM-en-307 Endress+Hauser...
  • Page 40: Operation With A Foundation Fieldbus Configuration Program

    • /452B48/1011/*.sym *.ffo *.cff The directory names have the following meaning: • 452B48: manufacturer ID of Endress+Hauser • 1011: device ID of Prosonic M Source of supply Host System Source of supply for the Device Description and Network Configuration files ABB (Field Controller 800) •...
  • Page 41 A FOUNDATION Fieldbus configuration tool offers two types of parameter representation: • Representation by parameter name Examples: "PAROPERATIONCODE", "PARRESET" • Representation by parameter label (identical to the labels on the display module VU331 and in an Endress+Hauser operation tool) Examples: "unlock parameter", "reset" Endress+Hauser...
  • Page 42: Operation With The Handheld Terminal Dxr375/Fc375

    You can navigate within the structure by the arrow keys and the "Enter" key. Alternatively, you can use the touch-screen functionality of the handheld terminal for navigation. (Double-click on a name opens the respective block or parameter). Endress+Hauser...
  • Page 43 CANCEL HELP Page Delete dsdmdm basic setup df das. asdas fa asas la. Prosonic M E+H_PROSONIC_M_XXXXXX tank shape: dome ceiling Endress+Hauser Device Revision 4 dome ceiling Block Tag Block Type Actual Mode horizontal cyl bypass RESOURCE... RES_BL... Auto stilling well SENSOR_B...
  • Page 44: Commissioning

    • 6.2 Unlocking the device • 6.3 Parameter reset • 6.4 Commissioning with display and operating module VU331 • 6.5 Commissioning with Endress+Hauser operating software • 6.6 Commissioning with FOUNDATION Fieldbus configuration tool • 6.7 Commissioning with handheld terminal DXR375/FC375...
  • Page 45 Enter "2457". Now parameters can be changed. Parameters affected Locking by the key combination affects the following parameters: • Parameters of the device specific blocks (Sensor Block, Diagnostic Block, Display Block) • Endress+Hauser service parameters 6.2.3 Locking parameter Locking Enter a number other than "2457" into the "unlock parameter" (0A4) function.
  • Page 46: Resetting The Device

    Sensorblock AI-Block 1 Input-Selector-Block Diagnoseblock AI-Block 2 Signal-Charact.-Block Display-Block PID Block Integrator-Block Endress+Hauser Service-Parameter L00-FMU4XXXX-02-00-00-YY-007 Performing the reset Resource Block, parameter RESTART; select the option "defaults". 6.3.2 Resetting the parameters of the transducer blocks " Caution! A reset may lead to impairment of the measurement. As a rule, a basic calibration is required after a reset.
  • Page 47 – "inactive": deactivates the tank map but does not delete it. It can be re-activated when required. – "active": activates the tank map. Resetting the tank map with an Endress+Hauser operating program In the function group "extended calibr." select the "cust. tank map" (055) function. Select the required option ("reset", "inactive" or "active") Resetting the tank map with a FOUNDATION Fieldbus configuration tool In the Sensor Block select the parameter PARCUSTTANKMAP (cust tank map).
  • Page 48: Commissioning By The Display And Operatig Module Vu331

    The "Basic setup" (00) function group lists all the functions which are required for a standard measurement task to commission the Prosonic M. When you have completed your input for a function, the next function appears automatically. In this way, you are guided through the complete calibration. Endress+Hauser...
  • Page 49 6.4.2 Application parameters Function "tank shape" (002) In this function, select one of the following options: dome ceiling horizontal cyl bypass stilling well ENDRESS+HAUSER Prosonic M (ultrasonic guide pipe) no ceiling sphere flat ceiling e.g. dumps, open levels chanels, weirs L00-FMU4xxxx-14-00-06-en-001 Function "medium property"...
  • Page 50 The averaging filters are set to small The filter and output damping are set signal are set to large values. values. to average values. -> Stable measured value -> Rapid reaction time -> Medium reaction time -> Possibly unstable measured value Endress+Hauser...
  • Page 51 Test: no filter Dusty bulk solids Bulk solids with rapid level change All the filters can be switched off for purposes of service and diagnosis. ENDRESS+HAUSER Prosonic M L00-FMU4xxxx-14-00-00-xx-007 L00-FMU4xxxx-14-00-00-xx-005 The filters are set to detect even The averaging filters are set to small All filters off relatively weak signals.
  • Page 52 Prosonic M signals a warning or an alarm, depending on your selection in the "in safety distance" (016) function. Function "full calibration" (006) In this function, enter the span F, i.e. the distance from the minimum level to the maximum level. Endress+Hauser...
  • Page 53 You can still edit the value. With manual suppression, the default value is 0 m. " Caution! The suppression range must end 0.5 m in front of the echo of the actual level. With an empty tank, do not enter E but E – 0.5 m. Endress+Hauser...
  • Page 54 Go back to the "check distance" (051) function. • Distance correct – Level incorrect -> Check the value of the "empty calibr." (005) function. Rücksprung zur Gruppenauswahl Nach der Störechoausblendung ist der Grundabgleich beendet und das Gerät springt automatisch in die Gruppenauswahl zurück. Endress+Hauser...
  • Page 55 If the cyclical envelope curve display is still active on the display, the measured value is updated at a slower cycle time. We therefore advise you to exit the envelope curve display after optimising the measuring point. To do this, press F. (The instrument does not leave the envelope curve display automatically.) Endress+Hauser...
  • Page 56 Vertical Zoom mode Press once more to switch to Vertical Zoom mode. is displayed. You now have the following options. • increases the vertical scale. • reduces the vertical scale. The display icon shows the current zoom factor ( L00-FMxxxxxx-07-00-00-yy-009 Endress+Hauser...
  • Page 57 • Press to exit the navigation. The set increases and shifts are retained. Only when you reactivate the "recording curve" (0E2) function the display settings return to their standard values. Endress+Hauser...
  • Page 58: Basic Setup With The Endress+Hauser Operating Program

    Commissioning Prosonic M - FOUNDATION Fieldbus Basic Setup with the Endress+Hauser operating program To carry out the basic setup with the operating program, proceed as follows: • Start the operating program and establish a connection. • Select the "basic setup" function group in the navigation window.
  • Page 59 – tank shape – medium property – process cond. ProsonicM-en-412 Basic Setup step 3/4: If "dome ceiling", "horizontal cyl", "..." is selected in the "tank shape" function, the following display appears on the screen: • empty calibr. • full calibr. ProsonicM-en-303 Endress+Hauser...
  • Page 60 • This step starts the tank mapping • The measured distance and the current measured value are always displayed in the header ProsonicM-en-304 6.5.1 Signal analysis via envelope curve After the basic setup, an evaluation of the measurement using the envelope curve is recommended. MicropilotM-en-306 Endress+Hauser...
  • Page 61 Prosonic M - FOUNDATION Fieldbus Commissioning 6.5.2 User-specific applications (operation) For details of setting the parameters of user-specific applications, see separate documentation BA240F/00/en "Prosonic M - Description of Instrument Functions" on the enclosed CD-ROM. Endress+Hauser...
  • Page 62: Commissioning With A Foundation Fieldbus Configuration Tool

    For commissioning of the device with a FOUNDATION Fieldbus configuration tool you need to know the DEVICE_ID, which consists of the following parts: Device_ID = 452B481011-XXXXXXXX whereby: 452B48 ID code for Endress+Hauser 1011 ID code for Prosonic M XXXXXXXX Device serial number, as printed on the nameplate 6.6.1 Fist setup Open the configuration tool and load the Device Descriptions (*.ffo, *.sym and - if required by...
  • Page 63 • You can open one of the FOUNDATION Fieldbus methods. Each method guides you automatically through a number of parameters which are required for a specific configuration task. The following sections describe the parametrization by the "basic setup" method. Open the FOUNDATION Fieldbus method "basic setup": Endress+Hauser...
  • Page 64 – by the display and operating module VU331 (see section 6.4.5) – by an Endress+Hauser operating program (see section 6.5.1) In the FOUNDATION Fieldbus configuration tool you can select from two types of parameter display: - parameter names (e.g. "PARTANKSHAPE") - label texts (e.g.
  • Page 65 – HI_LIM -> Limit value for the upper warning – LO_LIM -> Limit value for the lower warning – LO_LO_LIM -> Limit value for the lower alarm The limit values entered must be within the value range specified in the parameter group OUT_SCALE. Endress+Hauser...
  • Page 66 TARGET). However, this is only possible under the following conditions: – The function blocks are correctly connected with each other. – The parametrization of the AI Block is correct (see 6.6.4, steps 5 and 6). – The Resource Block is in operating mode AUTO. Endress+Hauser...
  • Page 67: Commissioning With The Handheld Terminal Dxr375/ Fc375

    (→ Page 62 ff.). The blocks should be parametrized in the following order: • the RESOURCE BLOCK • the SENSOR BLOCK (the "basic setup" method can be used for this, see page → ä 43) • the ANALOG INPUT BLOCKS Endress+Hauser...
  • Page 68: Troubleshooting

    • VU331: error symbol in the "measured value" (000) function • VU331 or Endress+Hauser operating program: in the "diagnostics" (0A) function group in the "present error" (0A0) function Only the highest priority error is displayed; in the case of multiple errors, you can scroll between the different error messages by pressing O or S.
  • Page 69 Error disappears when the level leaves the safety distance. Possibly reset the risk of overspill lock. ["safety settings" (01) function group, "ackn. alarm" (017) function]] A661 Sensor overtemperature A671 Linearisation incomplete Activate linearisation table W681 current out of range Carry out basic calibration; check linearisation Endress+Hauser...
  • Page 70 Device Failure Device needs maintenance now Unspecified Err W601 Uncertain configuration error GOOD Non specific Other Configuration Error W611 Uncertain configuration error GOOD Non specific Other Configuration Error W621 Uncertain Non specific GOOD Non specific simulation active No Error Endress+Hauser...
  • Page 71 Device needs maintenance now Unspecified Err (Alarm) E661 Uncertain Non specific GOOD Non specific Device needs maintenacne soon Unspecified Err (Warning) A671 Device Failure GOOD Non specific Configuration Error No Error W691 Uncertain Non specific GOOD Non specific Other Unspecified Err Endress+Hauser...
  • Page 72: Application Errors

    FF: Sensor Block, PARPROCESSCONDITION) measured value actual 3. Increase output damping (058). may jump sporadically to (FF: Sensor Block, PAROUTPUTDAMPING) higher expected levels 4. If necessary, select a different installation position and/or a larger sensor L00-FMR2xxxx-19-00-00-en-015 100% actual expected L00-FMR2xxxx-19-00-00-en-016 Endress+Hauser...
  • Page 73 1. Check application parameters (002), (003) and (004) (FF: Sensor Block, PARTANKSHAPE, PARMEDIUMCONDITION, PARPROCESSCONDITION) 100% 2. If necessary, select a different installation position and/or a larger sensor eingetreten 3. Align the sensor parallel to the product surface (particularly for bulk solids applications) E 641 erwartet L00-FMR2xxxx-19-00-00-en-018 Endress+Hauser...
  • Page 74: Maintenance And Repairs

    Spare parts are contained in suitable kits. They contain the related replacement instructions. All the spare parts kits which you can order from Endress+Hauser for repairs are listed with their order numbers in the section "Spare parts".
  • Page 75: Spare Parts (Housing Type F12)

    6 .. .3 x . 2 4 .. .2 > 7 0 ° C t > 8 5 ° C 65 20 FMU 40 FMU 41 FMU 42/44 FMU 43 L00-FMU4x-00-00-00-yy-007 Endress+Hauser...
  • Page 76 52015586 Power unit, CSA, 90...250V AC (housing F12) for electronics, 4-wire 40 Display 52005585 Display/operating module VU331 50 Probe with process connection 52010509 Sensor FMU40 G1-1/2 52010507 Sensor FMU40 NPT1-1/2 52010510 Sensor FMU41 G2 52010508 Sensor FMU41 NPT2 52023965 Sensor FMU42 52013543 Sensor FMU43 4", gasket Endress+Hauser...
  • Page 77 52000598 Hexagon nut (SW70) G2, bk, PC 65 Sealing kit 52010526 Sealing kit FMU4x Miscellaneous 52010545 Nameplate Prosonic M, modification Spare parts for FHX40 52018204 Adaption kit housing F12, 2-wire, FHX40 52018205 Adaption kit housing F12, 4-wire, FHX40 52016334 Cable FHX40, 20m Endress+Hauser...
  • Page 78: Spare Parts (Housing Type T12)

    6 .. .3 x . 2 4 .. .2 > 7 0 ° C t > 8 5 ° C FMU 40 FMU 41 FMU 42/44 L00-FMU4x-00-00-00-yy-008 Endress+Hauser...
  • Page 79 71037028 Sensor FMU44, gasket 55 Flanges 52023919 Flange, Uni-DN80/ANSI 3"/JIS 80A, PP 52023920 Flange, Uni-DN80/ANSI 3"/JIS 80A, PVDF 52023921 Flange, Uni-DN80/ANSI 3"/JIS 80A, 316L 52023922 Flange, Uni-DN100/ANSI 4"/JIS 100A, PP 52023923 Flange, Uni-DN100/ANSI 4"/JIS 100A, PVDF 52023924 Flange, Uni-DN100/ANSI 4"/JIS 100A, 316L Endress+Hauser...
  • Page 80 Maintenance and repairs Prosonic M - FOUNDATION Fieldbus 58 Hexagon nut 52000598 Hexagon nut (SW70) G2, bk, PC 52000599 Hexagon nut (SW60) G1-1/2, bk, PC 65 Sealing kit 52010526 Sealing kit FMU4x Miscellaneous 52010545 Nameplate Prosonic M, modification Endress+Hauser...
  • Page 81: Return

    Maintenance and repairs Return The following procedures must be carried out before a transmitter is sent to Endress+Hauser e.g. for repair or calibration: • Remove all residue which may be present. Pay special attention to the gasket grooves and crevices where fluid may be present.
  • Page 82: Contact Addresses Of Endress+Hauser

    Maintenance and repairs Prosonic M - FOUNDATION Fieldbus 8.10 Contact addresses of Endress+Hauser Contact addresses can be found on our homepage: www.endress.com/worldwide. If you have any questions, please do not hesitate to contact your Endress+Hauser representative. Endress+Hauser...
  • Page 83: Accessories

    >8 t >8 5° C 5° C L00-FMR2xxxx-00-00-06-en-001 Installation bracket for FMU 40/41 ø16 L00-FMU4x-00-00-00-de-001 • for FMU 40, G1½: Order No. 942669-0000 • for FMU 41, G2: Order No. 942669-0001 suited for NPT 1½" and 2" as well Endress+Hauser...
  • Page 84: Adapter Flange

    Version with conical thread(FAU 70 A) Process Connection 22 2" 150lbs FF, flange ANSI B16.5 24 3" 150lbs FF, flange ANSI B16.5 25 4" 150lbs FF, flange ANSI B16.5 Sensor Connection Thread NPT1-1/2 Thread NPT2 Flange Material 316L Polypropylene FAU 70 A Product designation Endress+Hauser...
  • Page 85: Cantilever

    FMU 41 316Ti/1.4571 52014138 galv. steel 52014137 • The 50 mm or 62 mm orifices serve for the mounting of the FMU 40 or FMU 41 sensor, respecitvely. • The 22 mm orifice may be used for an additional sensor. Endress+Hauser...
  • Page 86: Mounting Frame

    Height Material Order Code 700 mm galv. steel 919791-0000 700 mm 1.4301 (AISI 304) 919791-0001 1400 mm galv. steel 919791-0002 1400 mm 1.4301 (AISI 304) 919791-0003 Wall Bracket ø 33.7 L00-FMU4x-00-00-00-yy-006 Material Order Code galv. steel 919792-0000 316Ti/1.4571 919792-0001 Endress+Hauser...
  • Page 87: Mounting Bracket For Fmu 42/43/44

    L00-FMU4x-00-00-00-en-003.eps Commubox FXA291 The Commubox FXA291 connects Endress+Hauser field instruments with CDI interface (= Endress+Hauser Common Data Interface) to the USB interface of a personal computer or a notebook. For details refer to TI405C/07/en. Note! For the following Endress+Hauser instruments you need the "ToF Adapter FXA291" as an additional accessory: •...
  • Page 88: Remote Display Fhx40

    20m/65ft; for HART 20m/65ft; for PROFIBUS PA/FOUNDATION Fieldbus Additional option: Basic version Mounting bracket, pipe 1"/ 2" FHX40 - Complete product designation For connection of the remote display FHX40 use the cable which fits the communication version of the respective instrument. Endress+Hauser...
  • Page 89: Technical Data

    Device Revision 04 (hex) DD Revision 01 (hex) CFF Revision 01 (hex) ITK Version 4.61 ITK-Certification Driver-No. IT035900 Link Master (LAS) cabable Link Master / Basic Device yes; Default: Basic Device selectable Number VCRs Number of Link-Objects in VFD 24 Endress+Hauser...
  • Page 90 The signal characterizer block has two sections, each 40 ms standard rizer Block with an output that is a non-linear function of the respec- tive input. The non-linear function is determined by a sin- gle look-up table with 21 arbitrary x-y pairs. Endress+Hauser...
  • Page 91 The reaction time depends on the parameter settings. The minimum values are: • FMU40/41/42/43: min. 2 s • FMU44: min. 3 s Reference operating • Temperature = +20 °C conditions • Pressure = 1013 mbar abs. • Humidity = 50 % • Ideal reflective surface (e.g. calm, smooth fluid surface) Endress+Hauser...
  • Page 92 (hydrochloric acid, sulfuric acid, ...), dilute bases (caustic soda, ...), oils, greases, slurries, pastes, ... High vapor pressures or outgassing media (ethanol, acetone, ammonia, ...) can influence the accuracy. If conditions like these are present, please contact the Endress+Hauser support. 10.1.6 Ambient conditions Ambient temperature -40 °C ...
  • Page 93 Process conditions Process temperature -40°C ... +80°C A temperature sensor is integrated in the sensor for correction of the temperature-dependent time- of-flight. Process pressure • FMU 40/41: 0.7 bar ... 3bar abs. • FMU 42/43/44: 0.7 bar ... 2.5bar abs. Endress+Hauser...
  • Page 94: Appendix

    + sw-no. device id system parameters Note! The Default values of the parameters are typed in bold face. L00-FMU4xxxx-19-00-01-en-017 Endress+Hauser...
  • Page 95 . period , comma measured dist. measured level application par. detection window not modified modified reset distance unit temperature unit download mode parameter only param. + cust. map mapping only L00-FMU4xxxx-19-00-02-en-017 Endress+Hauser...
  • Page 96: Block Model Of The Prosonic M

    Primary value describe the e.g. scaling, status (main value) device (calibration, linearisation etc.) Secondary value (distance) Analog Input Function Block 2 parameters that are important to the process control system, Third value e.g. scaling, status (temperature) L00-FMU4XXXX-02-00-00-en-003 Endress+Hauser...
  • Page 97: Resource Block

    Shows any configuration, hardware, connection and system problems in the lock. The cause of the alert is to be seen in the subcode field. The function of the resource block parameters not described here can can be taken from the FOUNDATION Fieldbus specification, see "www.fieldbus.org". Endress+Hauser...
  • Page 98: Sensor Block

    A complete list of the configuration parameters can be found in the "Description of Instrument Functions", BA240F/00/en. If MODE_BLK refuses to be changed to AUTO, an error is present. Control all parameters, perform the required changes and try again to change MODE_BLK to AUTO. Endress+Hauser...
  • Page 99 Unsigned8 dynamic Auto, OOS measured temp. PARMEASUREDTEMPERATURE FloatingPoint dynamic Auto, OOS max. temp. limit PARMAXTEMPLIMIT FloatingPoint dynamic Auto, OOS max. meas. temp PARMAXMEASUREDTEMPERATURE FloatingPoint non-vol. Auto, OOS react. high temp PARONHIGHTEMPERATURE Unsigned8 static defect temp sens PARDEFECTTEMPERATURESENSOR Unsigned8 static Endress+Hauser...
  • Page 100 PARDISTANCEUNIT Unsigned16 static temperature unit PARTEMPERATUREUNIT Unsigned16 static download mode PARDOWNLOADMODE Unsigned8 static max meas dist 0D84 PARABSMAXMESSDIST FloatingPoint dynamic Auto, OOS max sample dist. 0D88 PAREDITRANGEMAXSAMPLEDIST FloatingPoint dynamic Auto, OOS present error PARACTUALERROR Unsigned16 dynamic Auto, OOS Endress+Hauser...
  • Page 101: Diagnostic Block

    PAROPERATIONCODE Unsigned16 non-vol. protocol+sw-no. PARPROTSOFTVERSIONSTRING VisibleString const Auto, OOS If MODE_BLK refuses to be changed to AUTO, an error is present. Control all parameters, perform the required changes and try again to change MODE_BLK to AUTO. Endress+Hauser...
  • Page 102: Display Block

    PARSEPARATIONCHARACTER Unsigned8 non-vol. Auto, OOS unlock parameter PAROPERATIONCODE Unsigned16 non-vol. If MODE_BLK refuses to be changed to AUTO, an error is present. Control all parameters, perform the required changes and try again to change MODE_BLK to AUTO. Endress+Hauser...
  • Page 103: Analog Input Block

    User description of the intended application of the block. BLOCK_ERROR Shows error status of software and hardware components – Out-of-Service: the block is in OOS mode – Simulation active: shows the setting of DIP-switch SIM. Input failure/process variable has BAD status. – configuration error Endress+Hauser...
  • Page 104 XD_SCALE_MAX - XD_SCALE_MIN The L_TYPE parameter influences the signal conversion: • Direct: PV = CHANNEL_VALUE • Indirect: FIELD_VALUE PV = x (OUT_SCALE_MAX - OUT_SCALE_MIN) + OUT_SCALE_MIN • Indirect square root: FIELD_VALUE PV = x (OUT_SCALE_MAX - OUT_SCALE_MIN) + OUT_SCALE_MIN Endress+Hauser...
  • Page 105 8 - 15 Critical alarms of increasing priority 11.7.8 Alarm status Parameter Description HI_HI_ALM The status of the HI_HI alarm HI_ALM The status of the HI alarm LO_ALM The status of the LO alarm LO_LO_ALM The status of the LO_LO alarm Endress+Hauser...
  • Page 106 A simulation is also possible by switching MODE_BLK to "MAN" and entering a value for OUT. Parameter Description SIMULATE Enables, sets and displays a simulated value, options: – enable/disable – simulated value – output value Endress+Hauser...
  • Page 107: List Of Start Indices

    View Objects Arithmetic Function Block 3040 View Objects Input Selector Function Block 3050 View Objects Signal Characterizer Function Block 3060 View Objects Integrator Function Block 3070 View Objects Sensor Block 4000 View Object Diagnostic Block 4100 View Object Display Block 4200 Endress+Hauser...
  • Page 108: Measuring Principle

    The interference echo suppression feature on the Prosonic M ensures that interference echos (e.g. from edges, welded joints and installations) are not interpreted as a level echo. 11.9.3 Calibration Enter the empty distance E and the span F to calibrate the device. Endress+Hauser...
  • Page 109 Prosonic M - FOUNDATION Fieldbus Appendix 11.9.4 Blocking distance Span F may not extend into the blocking distance BD. Level echos from the blocking distance cannot be evaluated due to the transient characteristics of the sensor. Endress+Hauser...
  • Page 110: Index

    ....... . . 35 operating menu ....... . 94 Endress+Hauser...
  • Page 111 Erklärung zur Kontamination und Reinigung Please reference the Return Authorization Number (RA#), obtained from Endress+Hauser, on all paperwork and mark the RA# clearly on the outside of the box. If this procedure is not followed, it may result in the refusal of the package at our facility.
  • Page 112 www.endress.com/worldwide BA239F/00/en/01.09 71089089 CCS/FM+SGML 6.0/ProMoDo 71089089...

Table of Contents