Vertical rooftop installation

Fitting the connecting chamber

Turn tee bolts 90° for all installation steps.
1. Position the connecting chamber
onto the mounting rails and click
into the retaining plates.
2. Align the connecting chamber.
The tube holders on the mounting
rails must be in line with those in
the connecting chamber; where
necessary, align with a piece of
string.
16
(cont.)
3. Tighten the connecting chamber
with the clamping brackets.
4. Where several collectors are
installed side-by-side, continue
with "Connecting the connecting
chamber" on page 24, otherwise
continue with "Fitting the connec-
tion set" on page 25.