Viessmann Vitocal 242-S Installation And Service Instructions Manual page 45

Compact heat pumps, split version for heating mode. compact heat pumps, split version for heating and cooling operation
Hide thumbs Also See for Vitocal 242-S:
Table of Contents

Advertisement

Power supply
(cont.)
X3.7
X3.6
X3.18/X2.1/X1.1
3
3
kWh
3/N
4
Fig. 45
Diagram excluding fuses and RCDs
Heat pump control unit (internal unit, luster termi-
A
nals, see chapter "Internal unit: Overview of con-
nections")
Instantaneous heating water heater (if installed)
B
Heat pump compressor (external unit)
C
Heat pump control unit power supply: See chapter
D
"Heat pump control unit power supply 230 V~".
Premium tariff meter
E
Ripple control receiver backup fuse
F
Ripple control receiver (contact open: power-OFF
G
enabled) with backup fuse
Economy tariff meter
H
Feed: TN-C system
K
Mains isolator
L
5 (400 V~)
(230 V~)
7
3
kWh
3/N
4
4
3
Installation sequence