Commissioning/service reports
Control parameters report
Parameters
"Temperature sensor at bottom of DHW
cylinder"
"Enable booster heaters for DHW heat-
ing"
"Enable electric heaters for DHW heat-
ing"
"Priority DHW heating with combi cylin-
der"
"Start attempts for DHW after high pres-
sure shutdown"
Solar
Parameter
"Type solar control unit"
"Max. collector temperature"
"Start hysteresis solar circuit pump"
"Stop hysteresis solar circuit pump"
"Flow rate solar circuit for calculating so-
lar yield"
"Display message incorrect circulation"
Electric booster heater
Parameter
"Enable instantaneous heating water
heater"
"Enable electric heaters for DHW heat-
ing"
"Enable instant. heating water heater for
central heating"
"Max. output instantaneous heating wa-
ter heater"
"Output for instant. heating water heater
at power-OFF"
"Dual mode temp instant. heating water
heater"
Internal hydraulics
Parameter
"Heat pump for drying a building"
"Time program for screed drying"
"Flow temperature for external demand"
"Starting time high efficiency circulation
pump"
114
(cont.)
Code
Delivered condition Commission-
600E
0
6014
0
6015
1
6016
0
6017
1
Code
Delivered condition Commission-
7A00
0
7A01
1300 (
7A02
70 (
7A03
30 (
7A07
100 l/h
7A09
1
Code
Delivered condition Commission-
7900
1
7901
0
7902
0
7907
3
790 A
0
790 B
500 (
Code
Delivered condition Commission-
7300
0
7303
0
730C
500 (
7365
Do not adjust
ing
ing
≙
130 °C)
≙
7 K)
≙
3 K)
ing
≙
50 °C)
ing
≙
50 °C)
Maintenance/
service
Maintenance/
service
Maintenance/
Service
Maintenance/
Service