Specification
Specification
(cont.)
Type AWT-AC
Connections
Heating water flow
Heating water return
Cold water
DHW
DHW circulation
Solar circuit flow
Solar circuit return
Liquid line
Pipe
■
7
Internal unit
■
External unit
■
Hot gas line
Pipe
■
7
Internal unit
■
External unit
■
Max. line length, liquid line, hot
gas line
Sound power of external unit at rated
heating output
(measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
3 K
5 K
■
At A7
±
/W35
±
in night mode dB(A)
3 K
5 K
■
At A7
±
/W55
±
Energy efficiency class to EU
Regulation no. 811/2013
Heating, average climatic condi-
tions
Low temperature applications
■
(W35)
Medium temperature applica-
■
tions (W55)
DHW heating
Draw-off profile L
■
Draw-off profile XL
■
400 V appliances
Type AWT-AC
Heating output data to EN 14511
(A2/W35)
Rated heating output
Fan speed
Power consumption
Coefficient of performance
(COP) in heating mode
Output control
122
241.A04
mm
Cu 28 x 1
mm
Cu 28 x 1
Rp
Rp
G
mm
UNF
UNF
mm
12 x 1
UNF
UNF
m
dB(A)
241.B10
kW
rpm
kW
ε
kW
241.A05
241.A07
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
¾
¾
¾
¾
1
1
DN 20 pipe sleeve for multi connect system
DN 20 pipe sleeve for multi connect system
6 x 1
10 x 1
⅝
⅝
⁷⁄₁₆
⅝
16 x 1
⅞
⅞
¾
⅞
20
30
60
62
58
58
++
++
A
A
+
+
A
A
A
A
241.B13
7.57
600
2.00
3.79
2.73 to 10.92
3.30 to 12.29
241.A10
241.A13
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
¾
¾
¾
¾
1
1
10 x 1
10 x 1
⅝
⅝
⅝
⅝
16 x 1
16 x 1
⅞
⅞
⅞
⅞
30
30
62
62
58
60
++
++
A
A
+
++
A
A
A
A
241.B16
9.06
690
2.42
3.72
¾
¾
1
10 x 1
⅝
⅝
16 x 1
⅞
⅞
30
63
60
++
A
+
A
A
11.2
690
3.45
3.20
—