Electric Connections For The Steamcraft - Cleveland SteamCraft 21CET8 Operation Installation Maintenance Manual

Electric convection steamers
Hide thumbs Also See for SteamCraft 21CET8:
Table of Contents

Advertisement

3. Test the Water Supply Lines
a. Make sure the Main External Power Switch is OFF.
b. Remove the control side panel to inspect water connections inside the SteamCraft.
c. Check all connections for proper tightness.
d. Open the water supply valves.
e. Check all lines and connections for leaks, both inside and outside the SteamCraft.
f.
Correct any leaks.
E. ELECTRIC CONNECTIONS for the SteamCraft
1. Install Electric Power Lines
a. See the SteamCraft Rating Plate for electric connection data.
The rating plate is located on the side panel OPPOSITE the control side.
The wiring diagram and the spare parts list are in the service connection area.
The main terminals are behind the control side panel in the service connection area.
b. The electrical supply must match all electrical and wiring requirements specified on the
rating plate and must be made in accordance with the following requirements:
1) The SteamCraft must be properly grounded by the installer.
2) The electrical power lines must be installed in accordance with:
The National Electric Code, ANSI/NFPA No. 70 LATEST EDITION (USA).
Canadian Electrical Code, CSA C22.2.
Any other applicable national, state, or local laws, codes, and regulations.
c. A main external disconnect switch should be installed near the SteamCraft as shown in
Figure 3-4.
A separate fuse or breaker sized to meet the line amps required by the SteamCraft
should be installed either as part of the main external power switch or in a separate
fuse box.
The fuse or breaker and disconnect switch combination is called the "Main External
Power Switch" (Figure 3-4).
d. Make the electrical connection using sufficient length of flexible conduit, per local code,
so the SteamCraft can be moved for service. Do NOT use a power cord.
e. Do NOT use a GFCI (GFI).
f.
Mechanically secure the flexible conduit to the SteamCraft's electrical access hole.
g. Check all cable and wire connections for size, location, and tightness.
h. Replace the control side panel and secure it to the SteamCraft before starting the
SteamCraft.
M AIN EXTERN AL
POW ER SW ITCH
Steam Craft
DRAIN LINE
COLD W ATER SUPPLY LINES
Figure 3-4
Main External Power Switch
14