Position And Level The Steamcraft; Water Connections For The Steamcraft - Cleveland SteamCraft 21CET8 Operation Installation Maintenance Manual

Electric convection steamers
Hide thumbs Also See for SteamCraft 21CET8:
Table of Contents

Advertisement

C. POSITION and LEVEL the SteamCraft
1. Move the SteamCraft into position.
2. Place a level along the bottom edge of the SteamCraft.
3. Use the adjustable legs of the SteamCraft or the adjustable legs of the Cleveland Range stand to
level the SteamCraft front-to-back and side-to-side.
Operating an out of level steamer can cause DEATH, INJURY, and EQUIPMENT DAMAGE.
Steamers must be level both front-to-back and side-to-side in all installations.
If a steamer is suspected to be out of level, shut it down at once and call your qualified
D. WATER CONNECTIONS for the SteamCraft
1. Water Supply Quality Requirements
a. Contact your Cleveland Range sales representative for details on how to provide water per
Minimum Water Quality Requirements in the Warranty, or how to increase the frequency of
maintenance, cleaning, and descaling.
b. Poor water supply quality degrades SteamCraft performance.
c. Check the quality of supply water before designing the water supply by contacting a local
water treatment specialist for on-premises water analysis.
d. Softened or chlorinated water damages the steam generator by increasing corrosion. Carbon
type filters are required before water enters the steam generator if supply water is softened or
chlorinated.
e. If a water treatment system must be installed to achieve acceptable water quality, install it
BEFORE connecting the water supply lines to a SteamCraft.
f.
If analysis shows that supply water is below Minimum Water Quality:
EITHER a water treatment system and/or carbon filter must be installed in the line
feeding the steam generator,
OR the frequency of maintenance, cleaning, and descaling must be increased beyond
that recommended in the maintenance schedule.
2. Connection of the Water Supply Lines
The Installer/Owner is responsible for the correct water connection of the SteamCraft.
When connecting water supply lines observe the following instructions, and any and all other
applicable national, state, and local codes and regulations.
NOTICE: Connect the SteamCraft to COLD WATER!
Never connect the SteamCraft to HOT WATER! The Condenser system and the steam
generator will not work properly if connected to HOT or WARM water.
NEVER operate an out of level steamer.
Cleveland Range authorized service agency immediately.
Using water outside the limits specified in this manual
without appropriate adjustment in the maintenance
schedule voids Warranty coverage.
DANGER
NOTICE
12