CHAPTER 7
INSTALLATION of the SteamCraft
A. SELECTING a LOCATION for the SteamCraft
1. For safe and efficient operation, observe the following criteria when selecting an operating
location for a SteamCraft
Improper lifting can result in DEATH, INJURY, AND EQUIPMENT DAMAGE.
A 21CET8 weighs 179 pounds empty and a 21CET16 weighs 220 pounds empty.
Use enough workers with training and experience lifting and moving heavy equipment to
place the steamer on the supporting surface. All clearance requirements above, and around
the steamcraft are the same for non-combustible locations as for combustible locations.
Failure to maintain required clearances and additional distances as needed can result
DEATH, INJURY and Equipment DAMAGE. Consult Sales and Services agencies as needed.
a. The location selected must be capable of supporting a SteamCraft at operational weight.
A 21CET8 weighs 179 lb empty and 274 lb operational.
A 21CET16 weighs 220 lb empty and 358 lb operational.
b. Position the SteamCraft so it will not tip or slide.
c. The operating surface must be level enough to allow leveling a SteamCraft with its adjustable
legs. A SteamCraft MUST be level both front to back and side to side before operation.
d. The location must include space for Operating and Service/Secondary Clearances and the
Exhaust Hood, if an Exhaust Hood is required. See Figure 1-2.
e. The location and area around it MUST be free from and clear of combustible materials.
f.
Proper air supply for ventilation is REQUIRED for and CRITICAL to safe, efficient operation of
a SteamCraft. Make sure the air vents of the SteamCraft are not blocked with or by anything.
g. Allow for sufficient extra distance if a "high heat source" (e.g. a broiler) is located next to the
SteamCraft. Contact Cleveland Range at 216-481-4900 or 1-800-338-2204 for recommendations.
h. The location must NOT be directly over a drain. Do NOT install a SteamCraft directly over a
drain because steam rising up out of the drain will adversely affect operation, hamper cooling
air circulation, and damage electrical and electronic components.
B. EXHAUST HOOD REQUIREMENTS
1. SteamCrafts may be required to be installed under an exhaust hood.
2. If an exhaust hood is required, the hood must extend over the SteamCraft and meet the
following requirements:
a. The SteamCraft must be vented in accordance with all local, state and national codes.
b. The exhaust hood must be sized for the cumulative ventilation requirements of all the
appliances in the area under the hood, including the SteamCraft. See Figure 1-2.
c. If an existing hood does not meet all specifications, a new one must be constructed over
the SteamCraft.
d. The venting hood system must include an interlock to prevent the operation of this appliance
without the operation of the ventilation hood if required by state or local code.
DANGER!