Keypad Timer Control Panel - Cleveland SteamCraft 21CET8 Operation Installation Maintenance Manual

Electric convection steamers
Hide thumbs Also See for SteamCraft 21CET8:
Table of Contents

Advertisement

F. KEYPAD TIMER CONTROL PANEL
1
2 3
4 5 6
7 8
9
0
ON
TIMED
MINITÉ
MARCHE
6
MANUAL
OFF
MANUEL
ARRET
Figure 4-2
1
2
3
4
5
1. TIMER Display
This four-digit display shows the minutes and seconds
remaining in the countdown.
The display reads from zero (00:00) to 99 minutes and
99 seconds (99:99).
Pause (PAUS) appears when the count down is
stopped by the START/STOP key or by the temperature
compensating circuit.
2. Number Keys 0-9
These keys set the number of minutes and seconds in
the timer count down.
Example: Pressing the number keys 1, 2, 3, 4, sets the
timer for 12 minutes and 34 seconds (12:34).
3. CLEAR Key
Press and hold this key for 5 seconds to zero (00:00)
the timer after it has been stopped.
The Timer must be reset to zero (00:00) ("zeroed") by
pressing this key before a new time can be set.
4. START/STOP Key
Press this key to start and stop the Timer.
Press and hold for 5 seconds to stop functions.
In TIMED mode, press this key to start and stop both
the Timer and steam flow.
In MANUAL mode, the steaming functions are
independent of the Timer.
Press this key to silence the buzzer.
5. POWER ON and GENERATOR FILL Switch with
Power On Indicator Light
This is the ON/OFF switch.
Turn this switch ON to power the control panel and fill
the steam generators.
6. TIMED/MANUAL Switch
The TIMED/MANUAL switch selects the Timed or
Manual Mode.
Using the KEYPAD Timer in Manual Mode:
NOTE: The Timer does NOT start or stop steaming in
Manual Mode.
1) Set and start the Timer.
2) The KEYPAD Timer counts down only when the
cooking compartment is at cooking temperature.
3) The buzzer sounds when the Timer reaches zero.
7