Neutral Adjustment (continued)
Tracking Adjustment
Hydro Change Procedure
Titan Service Manual
3438-774 Rev A
g321828
9. Stop the engine and lower the unit.
10. Verify proper neutral setting and tracking.
If the unit tracks or pulls to the RIGHT
Turn the LH adjustment nut 1 full turn clockwise. If more adjustment is needed,
turn the adjustment nut 1 full turn at a time.
If the unit tracks or pulls to the LEFT
Turn the RH adjustment nut 1 full turn clockwise. If more adjustment is needed,
turn the adjustment nut 1 full turn at a time.
g321828
1. Park the machine on a level surface and disengage the PTO. Stop the engine,
wait for all moving parts to stop, and remove key. Engage the parking brake
Figure 56
Figure 57
Page 6–5
Hydrostatic Drive System: Service and Repairs