Choke Control Assembly Replacement - Toro TITAN Service Manual

Hide thumbs Also See for TITAN:
Table of Contents

Advertisement

Throttle Control Assembly Installation (continued)

Choke Control Assembly Replacement

Choke Control Assembly Removal
Choke Control Assembly Installation
Chassis: Service and Repairs
8. Connect the battery by installing the positive cable first, then the negative
cable to the battery.
1. Park the machine on a level surface and disengage the PTO. Stop the engine,
wait for all moving parts to stop, and remove key. Engage the parking brake.
2. Disconnect the battery by removing the negative cable first, then the positive
cable from the battery.
3. Loosen the clamp securing the choke cable to the choke plate on the engine.
g323084
4. Remove the choke cable from the plate, noting the position of the cable
in the plate.
5. Remove the control panel assembly from the right console.
6. On the bottom side of the control panel assembly, loosen the jam nut
securing the choke lever in place. Remove the nut from the choke cable.
7. Pull the choke cable assembly through the control panel assembly and out
of the machine.
1. Route the choke cable through the control panel assembly
2. Thread the jam nut over the choke cable up to the control panel.
Figure 46