Installing the Controller Link Interface Unit

3-8
This section describes the method for installing and wiring the Controller Link Interface Unit.
It can be mounted to NS12 and NS10 PTs only. It cannot be mounted to an NS7 PT.
3-8-1

Controller Link Interface Unit Components

The following table shows the Controller Link Interface Unit's product configuration.
Model
NS-CLK21
Controller Link
terface Unit
Reference
Note
To comply with EC Directives (Low Voltage Directive) when mounting the Controller Link In-
terface Unit on the PT, attach the PT to a control panel that has been cut to fit to size. (Refer
to 3-1-3 Mounting the PT to the Control Panel for cutout dimensions.)
Name
NS-CLK001 Con-
Used for mounting the Controller Link
In-
nector Conversion
Support Board to the PT.
Board (1)
NS-CLK01
Con-
Connects the PT to the Controller Link
Network.
troller Link Sup-
port Board (1)
Connector (1)
Connects the communications cable
and Controller Link Support Board.
Cover (1)
Protects the connector and the Con-
troller Link Support Board.
Cable (1)
Connects the cover and the PT's
functional ground terminal to prevent
noise.
Screw (M3) (10)
These screws are used for:
• Securing the Connector Conversion
• Securing the cover to the back of
• Attaching the cable to the cover.
Instruction sheet
Instruction sheet for NS-CLK21
NS-CLK21 Units with lot number 12Y2 or later (manufactured on November 12, 2002 or later)
comply with EC Directives.

3-8 Installing the Controller Link Interface Unit

Components
Contents
Board to the back of the PT.
the PT.
3-39