Note: The length of low section will vary a little depending on the conditions.
Change in output voltage of R1401 on the LD-1014 board
1-6-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
1
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R1401 in the periphery of IC6800 on the LD-1014 board, turn the
2
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect
3
the camera control circuit (IC6000 of VC-1022 board) periphery.
Note: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-6-2. E : 62 : 11 [Shift Lens Overheating (Pitch)] Occurred
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] tab.
Check if the balanced optical steadyshot unit moves while setting the order 1.
2
If the balanced optical steadyshot unit does not move, replace the lens block (Note).
When the shift lens moved, proceed to the order 3.
While setting the order 1, measure with an oscilloscope the output voltage of C6816 and C6817 in the periphery of IC6800 on the LD-
3
1014 board to check the output voltage varies.
If the output voltage does not vary, replace the lens block (Note).
4
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R1401 in the periphery of IC6800 on the LD-1014 board, turn the power
6
ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
If the output voltage rises to 3V, replace the lens block (Note).
7
If it does not change as shown in Fig. 2, inspect the camera control circuit (IC6000 of VC-1022 board and IC6800 of LD-1014 board)
periphery.
Note: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
HDR-PJ800/PJ810/PJ810E/PJ820/PJ820E_L2
approx. 330 msec
Fig. 2
Procedure
Procedure
1-6-3.E : 62 : 12 [Shift Lens Overheating (Yaw)] Occurred
Order
1
Start the Adjust Manual in the Adjust Station and execute the [Measure to E:62:11/12] on the [SERVICE] tab.
Check if the balanced optical steadyshot unit moves while setting the order 1.
2
If the shift lens does not move, replace the lens block (Note).
When the balanced optical steadyshot unit moved, proceed to the order 3.
While setting the order 1, measure with an oscilloscope the output voltage of C6814 and C6815 in the periphery of IC6800 on the LD-
3
1014 board to check the output voltage varies.
If the output voltage does not vary, replace the lens block (Note).
4
When the output voltage varied, proceed to the order 5.
5
Turn the power OFF.
While measuring with an oscilloscope the output voltage of R1401 in the periphery
6
of IC6800 on the LD-1014 board, turn the power ON to check that the output voltage
immediately after the power on change as shown in Fig. 2.
If the output voltage rises to 3V, replace the lens block (Note).
7
If it does not change as shown in Fig. 2, inspect the camera control circuit (IC6000 of VC-1022 board and IC6800 of LD-1014 board)
periphery.
Note: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-6-4. E : 62 : 20 [Abnormality of Thermistor] Occurred
Order
1
Turn the power ON.
2
Confirm the connections of flexible flat cables and connectors between the lens block and LD-1014 board.
In case of no malfunction of connections, replace the lens block with new one (Note) . When the error has occurred in spite of the lens
3
replacement, replace LD-1014 board with new one.
Note: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-4