Connecting The Vent Pipe - Superior DRT2000 Series Installation And Operation Instructions For

Direct-vent gas fireplaces
Hide thumbs Also See for DRT2000 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces
Vent Restrictor with Horizontal Terminations
When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent
restrictor is required.
If installing more than 4 ft of vertical venting, install the restrictor (Figure 14), from inside or outside the unit, in the
inner fi replace collar. The vent restrictor is held in place by friction.
Table 14 - Effective Vent Length

Connecting the vent pipe

Secure Vent
lock connections (Figures 16 and 17). All of the fi replaces covered in this document are fi tted with collars having
locking inclined channels. The dimpled end of the vent components fi t over the fi replace/vent collar to create the
positive twist lock connection.
1. Align the dimpled end over the collar, adjusting the radial alignment until the four (4) locking dimples are aligned
2. Push the vent component against the collar until it fully engages, then twist the component clockwise, running
3. If desired, a #6 x 1/2" screw can be used at the joint, but is not required as the pipe will securely lock when
Where required, a telescopic vent section (SV4.5LA) may be used to provide the installer with an option to install
in tight and confi ned spaces, or where the vent run made up of fi xed length pieces develops a joint in a undesirable
location, or will not build up to the required length. The SV4.5LA Telescopic Vent Section has an effective length of
from 1-1/2" to 7" (38 to 191 mm). The SV4.5LA is fi tted with a locking inclined channel end (identical to a normal
vent section component) and a plain end with three (3) pilot holes. Slip the plain end over the locking channel end of
a standard SV4.5 vent component the required distance and secure with three (3) screws.
Figure 16 - Connecting vent
Vent elbows
Vent elbows are available in 90° and 45° confi gurations. Refer to Figure 18 for the SV4.5E45 and SV4.5E90 elbow
dimensions. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar
section to align with the required direction of the next vent run element.
1. Rotate the elbow in a clockwise direction (to avoid the possibility of unlocking any of the previously connected
22
Model
SV4.5L6
SV4.5L12
SV4.5L24
SV4.5L36
SV4.5L48
®
SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist
with the inlet of the four (4) inclined channels on the collar (Figure 16).
the dimples down and along the incline channels until they seat at the end of the channels.
NOTE: The unitized design of the Secure Vent
twisted (Figure 17).
components
Arrow
Dimple
Locking
Incline
Channel
Appliance Collar or
Vent Section
vent sections) for proper alignment (Figure 18). See Connecting the vent pipe for more information.
Effective Length
4-1/2"
10-1/2"
22-1/2"
34-1/2"
46-1/2"
®
components will engage and seal both the inner and outer vent pipe.
Figure 17 - Connected vent
components
Dimple
Locking
Arrow
Incline
Channel
900004-00, 03/2017
Figure 18 - Elbow Dimensions
4-13/16"
4 13/16 in.
(122 mm)
(122 mm)
Swivel Joint
Swivel Joint
Swivel Joint
Swivel Joint
°
(360°)
(360°)
(360
swivel)
°
(360
swivel)
SV4.5E45
SV4.5E45
SV4.5E90
SV4.5E90
(45° elbow)
°
(90° elbow)
(45
Elbow)
°
(90
Installation
8-1/8"
8 1/8 in.
(206 mm)
(206 mm)
Elbow)