3-15. Detection of errors related to the AW

3-15-1. Error detection under the normal conditions
F
<Data input screen>
A
B
C
D
<Bobbin check screen>
<AW error screen>
F is pressed or use of any function of the AW device is at-
If
tempted in the state no bobbin is loaded in the AW (in the state two
bobbins are not loaded) or in the state an error has been detected
on the data input screen, the AW error screen will be displayed.
If no bobbin is loaded in the AW device, the bobbin check screen
will be displayed. On the bobbin check screen, carry out the bobbin
loading operation to load two bobbins in the AW device to reset
the error. After the error is reset, the panel display returns to the
normal screen.
The following switches can be operated on the bobbin check
screen. Refer to
"3-10. Operating the AW" p.17
functions.
The button to be displayed differs according to the bobbin condi-
tion.
A : Bobbin take-out button
B : Empty bobbin loading button
C : Threaded bobbin loading button
D : Nozzle air button
In the case "E074 Remaining-thread removal error", "E075 Tan-
gling error", "E076 Bobbin winding error", "E077 Threading error,
or thread trimming" has been detected, the AW error screen will be
displayed.
On this screen, the error is reset by loading an empty bobbin or a
thread bobbin in the AW device. The item to be operated differs
with the error number.
E is pressed, the AW setting screen is displayed. On
When
this screen, settings of the AW can be changed.