H7CX (Counter Function)
Operation in Run Mode
Set values for each digit as required using the
1-stage Counter
2-stage Counter
Total and Preset Counter
Batch Counter
Dual Counter
Note:
indicates the displays at power-ON for the respective configurations.
and
Present Value
Present value
Shows the present count value.
Set value
Set Value (Set Value 1, Set Value 2)
Set the set value. When the present
value reaches the set value, signals
are output according to the specified
output mode.
Present value
Set value 1
Present value
Set value 2
Present Value/Set Value
Present value
Same as 1-stage counter.
Set value
Total Count Value
Shows the present total count value.
Total count value
Present Value/Set Value
Same as 1-stage counter.
Present value
Batch Count Value
Set value
Shows the number of times the count has
been completed for the present value.
Batch Count Set Value
Batch count value
Set the batch count set value. When the
Batch count set value
batch count value reaches the batch count
set value, batch output (OUT1) turns ON.
Dual Count Value
Shows the sum of the CP1 present value and CP2 present value when the
dual count calculating mode is ADD and shows the value obtained by
Dual count value
subtracting the CP2 present value from the CP1 present value when the dual
Dual count set value
count calculating mode is SUB.
Dual Count Set Value
Set the dual count set value. When the dual count value reaches the dual
count set value, signals are output according to the specified output mode.
CP1 present value
CP2 present value
CP1/CP2 Present Value
Show the present count values for CP1 and CP2 present values respectively.
keys. (
key only for 6-digit models.)
H7CX (Counter Function)
17