Connect Ac Power; Power Cord Specifications - Extreme Networks ExtremeSwitching Virtual Services Platform 4450GSX-PWR+ Installation Manual

Hide thumbs Also See for ExtremeSwitching Virtual Services Platform 4450GSX-PWR+:
Table of Contents

Advertisement

Table 13: DC power supply specifications
Description
Output power
Input voltage
Input current
Output voltage
Output current
Mean time between failures
The following table describes the regulatory DC power specifications for the VSP 4450GSX-DC
switch. The regulatory DC power specifications are based on the maximum rated capacity of the
power supplies and are not based on typical power consumption, which is lower.
Table 14: DC power specifications
Input Current:
Input Voltage:
Power Consumption:
Thermal Rating:

Connect AC power

This section explains power cord specifications and how to connect AC power.

Power cord specifications

To connect AC power to the switch, you need an appropriate AC power cord as described in the
following table, also see the following table for plug specifications.
Table 15: International power cord specifications
Country and Plug Specification
Continental Europe:
• CEE7 standard VII male plug
August 2018
4450GSX-DC
25A
12VDC
• Typical: 116W
• Maximum: 164.6W
508 BTU/Hr
Installing the Virtual Services Platform 4450GSX-PWR+
DC-DC-12V-300 W
300 W
48 V DC
10 A
12 V DC
25 A
293,000 hours
Specifications
• 220 or 230VAC
• 50 Hz
• Single phase
Connect AC power
Typical Plug
Table continues...
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents