2.6.2 Wiring Examples - Siemens RUGGEDCOM RSG2100F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RSG2100F:
Table of Contents

Advertisement

Installing the Device
2.6.2 Wiring Examples
7.
8.
2.6.2
Wiring Examples
The following illustrate how to connect power to single and dual power supplies.
18
Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power
source to the chassis ground terminal on the device. Make sure the lug is tight-
ened to 1.7 N·m (15 lbf·in).
1
Stainless Steel Stud
1
#6-32 Screw
2
#6 Ring Lug
3
Figure 2.7
Chassis Ground Connection
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the de-
vice is powered.
Install the terminal block cover.
2
3
RUGGEDCOM RSG2100F
Installation Manual, 01/2020, C79000-G8976-1344-07

Advertisement

Table of Contents
loading

Table of Contents