Operating Environment; Mechanical Specifications; Dimension Drawings - Siemens RUGGEDCOM RSG2100F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for RUGGEDCOM RSG2100F:
Table of Contents

Advertisement

Mode
Connec-
tor Type
e
SM
SC
a
All cabling is duplex type unless specified otherwise.
b
Typical.
c
All optical power numbers are listed as dBm averages.
d
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of
patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
e
Operating temperature range of -20 to 85 °C (-4 to 185 °F) .
5.6

Operating Environment

The RUGGEDCOM RSG2100F is rated to operate under the following environmental
conditions.
Ambient Operating
Temperature
Ambient Storage Tem-
perature
Ambient Relative Hu-
midity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure.
b
Non-condensing
5.7

Mechanical Specifications

Weight
Ingress Protection
Enclosure
5.8

Dimension Drawings

Note
All dimensions are in millimeters, unless otherwise stated.
Note
Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stat-
ed.
RUGGEDCOM RSG2100F
Installation Manual, 01/2020, C79000-G8976-1344-07
Cable
Tx λ
b
Type
(nm)
Minimum Maximum
a
(µm)
9/125
1550
-40 to 85°C (-40 to 185 °F)
a
-40 to 85°C (-40 to 185 °F)
5% to 95%
b
2000 m (6562 ft)
5.2 kg (11.5 lbs)
IP20
18 AWG Galvanized Steel
c
Tx (dBm)
Rx Sen-
sitivity
(dBm)
0
5
-23
Technical Specifications
5.6 Operating Environment
Rx Sat-
Distance
d
uration
(km)
c
c
(dBm)
-3
70
Pow-
er Bud-
get (dB)
23
37

Advertisement