RUGGEDCOM RSG2288
Installation Guide
06/2017
RC1045-EN-10
Preface
Introduction
Installing Device
Communication Ports
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSG2288

  • Page 1 Preface Introduction Installing Device RUGGEDCOM RSG2288 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 06/2017 RC1045-EN-10...
  • Page 2: Security Information

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RSG2288 Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RSG2288 Installation Guide...
  • Page 5 RUGGEDCOM RSG2288   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Precision Time Protocol (PTP) Support ....................
  • Page 6   RUGGEDCOM RSG2288 Table of Contents Installation Guide Chapter 3 Communication Ports ..................3.1  Copper Ethernet Ports ......................... 22 3.2  Fiber Optic Ethernet Ports ......................23 3.3  SFP Transceivers ......................... 24 3.4    BNC Ports ........................... 24 3.5  GBIC Optic Ethernet Ports ......................25 3.5.1  Installing a GBIC Optical Port ....................
  • Page 7 Installation Guide Preface Preface This guide describes the RUGGEDCOM RSG2288. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR •...
  • Page 9: Introduction

    Support for front or rear mount connectors coupled with support for multiple fiber connector types (SFP, GBIC, LC, SC) without loss of port density makes the RUGGEDCOM RSG2288 highly versatile and suitable for any application. The RUGGEDCOM RSG2288 is packaged in a rugged, galvanized steel enclosure with industrial grade DIN, panel, or 48 cm (19 in) rack-mount mounting options.
  • Page 10: Communication Ports

    Section 1.2 Description The RUGGEDCOM RSG2288 features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 11: Precision Time Protocol (Ptp) Support

    RUGGEDCOM RSG2288 Chapter 1 Installation Guide Introduction Port Status Indicator LEDs Port status indicator LEDs indicate the operational status of each port, dependent on the currently selected mode. Mode Color/State Description Status Green (Solid) Link detected Green (Blinking) Link activity...
  • Page 12: Supported Time Synchronization Sources

    • Section 1.3.2, “IEEE 1588 Support” • Section 1.3.3, “AM and TTL Outputs” Section 1.3.1 Supported Time Synchronization Sources The following time synchronization sources are supported by the RUGGEDCOM RSG2288, with or without the PTP card: Without With Synchronization Source Description PTP Card...
  • Page 13: Ieee 1588 Support

    PPx provides a generic pulse per X second to sychronize external devices. û ü Section 1.3.2 IEEE 1588 Support RUGGEDCOM RSG2288 supports various IEEE 1588 time synchronization capabilities and provides synchronization in 2-step mode. Supported Clock Types IEEE 1588 Clock Type Without PTP Card...
  • Page 14 Chapter 1 RUGGEDCOM RSG2288 Introduction Installation Guide The number of devices that can be connected to the AM OUT and TTL Out ports is dependent on the cabling type and length, as well as the input impedances of the devices. The following simplified circuit schematic shows the interface between an IRIG-B source and connected devices.
  • Page 15: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 16: Certification

    Connect power to the device and ground the device to safety Earth. Connect the device to the network. Configure the device. Section 2.2 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSG2288: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device.
  • Page 17: Protection On Twisted-Pair Data Ports

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 18: Mounting The Device

    Section 2.4.1 Mounting the Device to a Rack The RUGGEDCOM RSG2288 can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters. The adapters can be installed at the front or rear of the chassis.
  • Page 19: Mounting The Device On A Din Rail

    Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RSG2288 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 20: Mounting The Device To A Panel

    Section 2.4.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSG2288 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 21: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROS. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for the RUGGEDCOM RSG2288. The following shows the proper relay connections.
  • Page 22: Connecting Power

    The RUGGEDCOM RSG2288 supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM RSG2288 can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies . The screw-type terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 23: Connecting Ac Or Dc Power

    RUGGEDCOM RSG2288 Chapter 2 Installation Guide Installing Device • Section 2.6.2, “Wiring Examples” Section 2.6.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the field, remove the metal jumper.
  • Page 24 Chapter 2 RUGGEDCOM RSG2288 Installing Device Installation Guide Figure 8: Terminal Block Wiring 1. Screw-Type Terminal Block    2. Pluggable Terminal Block    3. Jumper    4. Positive/Live (+/L) Terminal    5. Negative/Neutral (-/N) Terminal (-/N)    6. Surge Ground Terminal    7. Chassis Ground Terminal Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
  • Page 25: Wiring Examples

    RUGGEDCOM RSG2288 Chapter 2 Installation Guide Installing Device Section 2.6.2 Wiring Examples The following illustrate how to connect power to single and dual power supplies. Figure 10: Single AC Power Supply Figure 11: Single DC Power Supply Wiring Examples...
  • Page 26 Chapter 2 RUGGEDCOM RSG2288 Installing Device Installation Guide Figure 12: Dual AC Power Supply Figure 13:  Dual DC Power Supply Wiring Examples...
  • Page 27: Connecting To The Device

    Connecting to the Device The following describes the various methods for accessing the ROS console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG2288. RS232 Console Port Connect a workstation directly to the RS232 console port to access the boot-time control and ROS interfaces. The console port provides access to ROS's console and Web interfaces.
  • Page 28: Configuring The Device

    Chapter 2 RUGGEDCOM RSG2288 Installing Device Installation Guide Name Description Comment RJ45 Male Female Receive Data (to DTE) Transmit Data (from DTE) Clear to Send Read to Send Ring Indicator The DSR, DCD and DTR pins are connected together internally.
  • Page 29 Chapter 3 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RSG2288 can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 16: Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2288 chassis: •...
  • Page 30: Copper Ethernet Ports

    Section 3.1 Copper Ethernet Ports The RUGGEDCOM RSG2288 supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 male connectors. The RJ45 connectors are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 31: Fiber Optic Ethernet Ports

    RUGGEDCOM RSG2288 Chapter 3 Installation Guide Communication Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi-Directional Pair B+ Reserved (Do BI_DC+ Transmit Data+ Not Connect) or Bi-Directional Pair C+ Reserved (Do BI_DC- Receive Not Connect) Data- or Bi- Directional Pair C-...
  • Page 32: Sfp Transceivers

    The RUGGEDCOM RSG2288 features two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. The following SFP transceivers are compatible with the RUGGEDCOM RSG2288. For more information, including installation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog [https://support.industry.siemens.com/cs/ca/en/view/109482309] .
  • Page 33: Gbic Optic Ethernet Ports

    Inputs are controlled by RUGGEDCOM ROS and only one can be active at any time. For information about activating an input, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSG2288. The color of the Sync LED on the front panel of the PTP module indicates the status of the incoming timing signal: •...
  • Page 34: Installing A Gbic Optical Port

    To install a GBIC optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 35: Removing A Gbic Optical Port

    RUGGEDCOM RSG2288 Chapter 3 Installation Guide Communication Ports Release the latches and make sure the port is locked in place. IMPORTANT! Only remove the dust plug when ready to connect a cable to the GBIC optical port. Remove the dust cover from the port and store for future use.
  • Page 36 Chapter 3 RUGGEDCOM RSG2288 Communication Ports Installation Guide Removing a GBIC Optical Port...
  • Page 37: Technical Specifications

    Section 4.8, “Mechanical Specifications” Section 4.1 Power Supply Specifications The RUGGEDCOM RSG2288 can be equipped with the following power supplies: CAUTION! Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power input is above or below the specified input range.
  • Page 38: Failsafe Relay Specifications

    NOTE • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 39: Fiber Optic Ethernet Port Specifications

    RUGGEDCOM RSG2288 Chapter 4 Installation Guide Technical Specifications Cable Type > CAT-5 Wiring Standard TIA/EIA T568A/B Maximum Distance 100 m (328 ft) Isolation 1.5 kV Auto-Negotiating Shielded or unshielded. Auto-crossover and auto-polarity. Typical distance. Dependent on the number of connectors and splices.
  • Page 40 All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances.
  • Page 41: Ptp Specifications

    RUGGEDCOM RSG2288 Chapter 4 Installation Guide Technical Specifications Section 4.6 PTP Specifications IRIG-B PWM Input Specifications Parameter Typical Value Input Voltage TTL-Compatible Input Impedance >200 kΩ IRIG-B PWM Output Specifications Parameter Typical Value Output Current (I 100 mA Output Voltage (V...
  • Page 42: Operating Environment

    Chapter 4 RUGGEDCOM RSG2288 Technical Specifications Installation Guide Section 4.7 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C (-40 to 185 °F) Ambient Temperature as measured from a 30 cm radius surrounding the center of the enclosure.
  • Page 43: Dimension Drawings

    RUGGEDCOM RSG2288 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. NOTE Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stated. 438.15 Figure 26: Overall Dimensions...
  • Page 44 Chapter 5 RUGGEDCOM RSG2288 Dimension Drawings Installation Guide 32.77 21.08 11.68 479.29 461.01 4.57 Figure 27: Rack Mount Dimensions...
  • Page 45 RUGGEDCOM RSG2288 Chapter 5 Installation Guide Dimension Drawings 486.4 476.3 10.4 11.4 Figure 28: Panel and DIN Rail Mount Dimensions...
  • Page 46 Chapter 5 RUGGEDCOM RSG2288 Dimension Drawings Installation Guide...
  • Page 47: Certification

    RUGGEDCOM RSG2288 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSG2288 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 48: European Union (Eu)

    Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens ”.
  • Page 49: Ised

    Installation Guide Certification Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 This device was designed and manufactured using a certified ISO (International Organization for Standardization) quality program that adheres to the following standard: •...
  • Page 50: Emc And Environmental Type Tests

    Certification Installation Guide Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RSG2288 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 NOTE • If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance errors may occur but recovery is automatic.
  • Page 51 EMC Immunity Type Tests per IEEE 1613 NOTE The RUGGEDCOM RSG2288 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 52: Environmental Type Tests

    Chapter 6 RUGGEDCOM RSG2288 Certification Installation Guide Description Test Levels AC Power Ports 5 kV Dielectric Strength Signal Ports 2 kV DC Power Ports 1.5 kV AC Power Ports 2 kV Damped Oscillatory Enclosure Ports 100 A/m Magnetic Field Environmental Type Tests...

Table of Contents