Siemens SIMATIC NET RUGGEDCOM RSG2300P Installation Manual

Siemens SIMATIC NET RUGGEDCOM RSG2300P Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG2300P:

Advertisement

Quick Links

Edition
04/2022
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RSG2300P
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RSG2300P

  • Page 1 Edition 04/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RSG2300P https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2300P Communication Ports Technical Specifications Installation Manual Certification 04/2022 C79000-G8976-1047-18...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Fiber Optic Ethernet Ports ................... 26 SFP Transceivers ....................27 GBIC Optic Ethernet Ports ..................27 4.5.1 Installing a GBIC Optical Port ................28 4.5.2 Removing a GBIC Optical Port ................29 Technical Specifications ...................... 31 Power Supply Specifications ................31 PoE Power Supply Specifications ................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RSG2300P is available online at https://support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RSG2300P is a rugged, Power over Ethernet (PoE) enabled, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility substation, railway and industrial environments. The RUGGEDCOM RSG2300P’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reliability and advanced cyber security and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control...
  • Page 11: Description

    Introduction 1.2 Description • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Conformal coated printed circuit boards (optional) • 18 AWG galvanized steel enclosure Universal Power Supply Options • Fully integrated power supplies • Device power supply: 24 VDC (10-36 VDC), 48 VDC (36-59 VDC), 88-300 VDC or 85-264 VAC •...
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials Mode Color/State Description Green (Blinking) Link activity No link detected Duplex Green Full duplex mode Orange Half duplex mode No link detected Speed Green (Solid) 100 Mbps Green (Blinking) 1000 Mbps Orange (Solid) 10 Mbps No link detected Display Mode Indicator LEDs The display mode indicator LEDs indicate the current display mode...
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Supported Fiber Optic Cables

    Introduction 1.5.3 Supported Fiber Optic Cables Cabling 1000Base- Required Action Category TX Compliant Verify TIA/EIA-568-A compliance. No action required. New installations should be designed with Category 5e or higher. No action required. > 6 Connector and wiring standards to be determined. Follow these recommendations for copper data cabling in high electrical noise environments: •...
  • Page 15 Introduction 1.5.3 Supported Fiber Optic Cables RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2300P is designed for maximum mounting and display flexibility.
  • Page 18: Mounting The Device To A Rack

    Installing the Device 2.3.1 Mounting the Device to a Rack Note For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to "Dimension Drawings (Page 35)". 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2300P can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters.
  • Page 19: Mounting The Device On A Din Rail

    Installing the Device 2.3.2 Mounting the Device on a DIN Rail To secure the device to a standard 48 cm (19 in) rack, do the following: Note The device can be ordered with the communication ports located at the front or rear of the device.
  • Page 20: Mounting The Device To A Panel

    Installing the Device 2.3.3 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.2 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adapter Figure 2.3 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 22: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2300P supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RSG2300P can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power supply and PoE ports.
  • Page 23: Connecting Ac Or Dc Power

    Installing the Device 2.5.1 Connecting AC or DC Power • Equipment must be installed according to applicable local wiring codes and standards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: NOTICE Electrical hazard –...
  • Page 24 Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Chassis Ground Connection Figure 2.5...
  • Page 25: Connecting External Poe Power

    For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https:// support.industry.siemens.com/cs/ww/en/view/109478699.
  • Page 26 Installing the Device 2.5.2 Connecting External PoE Power To connect an external power supply for the PoE ports, do the following: NOTICE Electrical hazard – risk of damage to equipment Only connect the external PoE power supply to the terminals 5 and 7. Remove the terminal block cover.
  • Page 27: Wiring Examples

    Installing the Device 2.5.3 Wiring Examples If the external PoE power supply features a chassis ground connection, connect the ground terminal on the power supply to terminal 4 on the terminal block. DANGER Electrocution hazard – risk of death, serious personal injury and/or damage to the device Make sure the supplied terminal block cover is always installed before the device is powered.
  • Page 28 Installing the Device 2.5.3 Wiring Examples Figure 2.9 AC and 48 VDC PoE Power Supply RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 29 Installing the Device 2.5.3 Wiring Examples RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 30: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG2300P console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOMROS Configuration Manual" for the RUGGEDCOM RSG2300P.
  • Page 31: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2300P console and Web interfaces via the device's IP address.
  • Page 32: Communication Ports

    Communication Ports The RUGGEDCOM RSG2300P can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2300P chassis: • Slot 1 supports a two-port fiber or copper module, or an additional two-port 10/100Base-TX 802.3af (PoE) module for extra PoE ports •...
  • Page 33: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports Port LED Figure 4.2 Port LEDs LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Copper Ethernet Ports The RUGGEDCOM RSG2300P supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 male connectors.
  • Page 34: Poe Ports

    Communication Ports 4.2 PoE Ports Name Description 10/100Base-TX 1000Base-TX BI_DA+ Receive Data+ or Bi- Directional Pair A+ BI_DA- Receive Data- or Bi- Directional Pair A- BI_DB+ Transmit Data+ or Bi- Directional Pair B+ Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi- Directional Pair C+ Reserved (Do Not Connect) BI_DC-...
  • Page 35: Fiber Optic Ethernet Ports

    Communication Ports 4.3 Fiber Optic Ethernet Ports State Description Yellow (Solid) Link established Yellow (Blinking) Transmitting/receiving No link detected Pin-Out The pin-out for the PoE ports is as follows:   Description RX + and Power - RX - and Power - TX + and Power + Reserved (Do Figure 4.4...
  • Page 36: Sfp Transceivers

    "RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]". IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. GBIC Optic Ethernet Ports GBIC (Gigabit Interface Converter) optic Ethernet ports are available with SC (Standard or Subscriber Connector) connectors.
  • Page 37: Installing A Gbic Optical Port

    To install a GBIC optical port, do the following: NOTICE Electrical hazard – risk of damage to equipment Use only components certified by Siemens with RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability have not been properly assessed.
  • Page 38: Removing A Gbic Optical Port

    Communication Ports 4.5.2 Removing a GBIC Optical Port Squeeze the latches on either side of the port and insert the port into the socket. GBIC Optical Port Module Socket Locking Latch Figure 4.10 Installing a GBIC Optical Port Release the latches and make sure the port is locked in place. NOTICE Only remove the dust plug when ready to connect a cable to the GBIC optical port.
  • Page 39 Communication Ports 4.5.2 Removing a GBIC Optical Port Disconnect the cable from the port and install the dust cap to the cable end. Squeeze the latches on either side of the port and pull it from the socket. Socket GBIC Optical Port Locking Latch Figure 4.11 Removing a GBIC Optical Port...
  • Page 40: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2300P can be equipped with the following power supplies: NOTICE Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range. Note For specifications on the PoE power supply, refer to "PoE Power Supply Specifications...
  • Page 41: Failsafe Relay Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 42: Fiber Optic Ethernet Port Specifications

    14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
  • Page 43 All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. GBIC Gigabit (1 Gbps) Transceiver Specifications Note GBIC transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless...
  • Page 44: Operating Environment

    Technical Specifications 5.7 Operating Environment Operating Environment The RUGGEDCOM RSG2300P is rated to operate under the following environmental conditions. Ambient Operating -40 to 85°C (-40 to 185 °F) Temperature Ambient Storage -40 to 85°C (-40 to 185 °F) Temperature Ambient Relative 5% to 95% Humidity Maximum Altitude...
  • Page 45 Technical Specifications 5.9 Dimension Drawings 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 46 Technical Specifications 5.9 Dimension Drawings 32.77 21.08 11.68 479.29 470.4 461.0 Figure 5.2 Rack Mount Dimensions RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 47 Technical Specifications 5.9 Dimension Drawings 11.7 10.4 476.3 486.4 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RSG2300P Installation Manual, 04/2022, C79000-G8976-1047-18...
  • Page 48: Certification

    6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: EN 62368-1 • Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 49: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 50: Ised

    Certification 6.1.5 ISED 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6 This device was designed and manufactured using a certified ISO (International...
  • Page 51: Other Approvals

    China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https:// support.industry.siemens.com/cs/ww/en/view/109738831. 6.1.9 Other Approvals This device meets the requirements of the following additional standards: •...
  • Page 52 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels AC Power Ports ±4 kV Line-to- Ground, ±2 kV Line-to-Line IEC 61000-4-6 Induced Signal Ports 10 V (Conducted) RFI DC Power Ports AC Power Ports Earth Ground Ports IEC 61000-4-8 Magnetic Field Enclosure Ports...
  • Page 53 Certification 6.2 EMC and Environmental Type Tests temporary communication loss, while Class 2 requires error-free and interrupted communications. Description Test Levels Enclosure Contact ±2 kV ±8 kV Enclosure Air ±15 kV Radiated RFI Enclosure Ports 35 V/m Fast Transient Signal Ports 4 kV @ 2.5 kHz DC Power Ports 4 kV...
  • Page 54 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...

Table of Contents