11) Connect the thermistor leads through the bushing of the control box to the K3 connector
on the control board.
Do not cut the leads of the thermistor.
1) Replace the control box cover and the panels in their correct positions.
13) Turn on the power supply.
M. Removal and Replacement of Fan Motor - Air-Cooled and Remote
Air-Cooled Models
Note: When replacing a fan motor with defective winding, it is recommended that a new
capacitor be installed.
1) Turn off the power supply.
) Remove the panels.
3) Remove the junction box cover from the remote condenser unit (remote air-cooled
models).
4) Disconnect the fan motor wires.
5) Remove the fan motor bracket and fan motor.
6) Install the new fan motor, connect the fan motor wires, and replace the removed parts
in the reverse order of which they were removed.
7) Replace the panels in their correct positions.
8) Replace the junction box cover in its correct position (remote air-cooled models).
9) Turn on the power supply.
N. Removal and Replacement of Inlet Water Valve
1) Turn off the power supply.
) Close the icemaker water supply line shut-off valve. Open the icemaker water supply
line drain valve.
3) Remove the front panel.
4) Disconnect the valve outlet tubing by releasing the clamp.
5) Loosen the fitting nut. Be careful not to lose the washer.
6) Disconnect the terminals from the inlet water valve.
7) Remove the bracket and valve from the unit.
8) Install the new valve. Replace the removed parts in the reverse order of which they
were removed. Make sure the washer is in place in the fitting nut.
9) Close the icemaker water supply line drain valve. Open the icemaker water supply line
shut-off valve.
10) Turn on the power supply.
CAUTION
47