Hoshizaki KM1601SRH350 Service Manual page 33

Stackable crescent cuber
Table of Contents

Advertisement

Problem
[1]Freeze cycle time is
too long. (continued)
[]All ice formed on
evaporator does not
fall into bin in harvest
cycle.
Possible Cause
c) Evaporator
d) Spray Tubes
e) Water Pump
f) Thermistor
g) Refrigerant Charge
h) Expansion Valve
i) Control Board
a) Evaporator
b) Ambient and/or Water
Temperature
c) Water Supply Line
d) Water System
e) Inlet Water Valve
f) Spray Tubes
g) Thermistor
h) Hot Gas Valve
i) Expansion Valve
j) Liquid Line Valve
(if applicable)
1. Scaled up.
. Damaged.
1. Dirty.
. Out of positon.
1. RPM too slow.
1. Loose or
disconnected.
1. Low charge.
1. Bulb loose.
. Operating erratically.
1. Defective.
1. Scaled up.
. Damaged.
1. Too cool.
1. Water pressure too
low.
1. Water supply line too
small; requires 1/"
OD line dedicated per
machine.
. Water filter clogged or
flow rate too small.
1. Dirty mesh filter or
orifice.
. Diaphragm does not
close.
1. Dirty.
. Out of position.
1. Loose or
disconnected.
1. Coil winding open.
. Plunger does not
move.
3. Wiring to hot gas
valve.
1. Open.
1. Continues to open in
harvest cycle.
33
Remedy
1. Clean.
. Replace.
1. Clean.
. Place in position.
1. See chart 1. [5].
1. Reattach or connect. See
"II.D. Harvest Control -
Thermistor."
1. Check for leaks. Recover,
repair, evacuate, and
recharge.
1. Secure bulb.
. Check and replace.
1. See "II.C.4. Control Board
Check Procedure."
1. Clean.
. Replace.
1. Increase temperature.
1. Check and get
recommended pressure.
1. Increase water line size.
. Replace filter or install a
higher flow rate filter.
1. Clean.
. Check for water leaks with
icemaker off.
1. Clean.
. Place in position.
1. Reattach or connect. See
"II.D. Harvest Control -
Thermistor."
1. Replace.
. Replace.
3. Check for loose
connection or open, and
replace.
1. Check and replace.
1. Check operation in harvest
cycle and replace.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km1900sah350M2100srh350

Table of Contents