Facing Material; Finishing Material - Heat & Glo ST-550TM-IPI Owner's Manual

Hide thumbs Also See for ST-550TM-IPI:
Table of Contents

Advertisement

C. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or finishing materials must not interfere with
air flow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or finishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the finished wall and appliance top
and sides using a 300°F minimum sealant. Refer to
Figure 13.16.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
= COMBUSTIBLE MATERIAL
9 in.
0 in.
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 13.16
46
0 in.
Heat & Glo • ST-550TM-IPI • 2142-900 Rev. S • 3/20
D. Finishing Material
Only doors certified for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used. Once you have determined what kind of door
and finishing material is going to be used on the fireplace,
you may use the table below which shows the door mod-
els and the finishing material thickness allowed. For an
inside fit there is an available template to assist with siz-
ing the finishing material.
ST-550TM-IPI
DOOR
FIT
Overlap
Modern
Inside
FINISH MATERIAL
MAXIMUM
SEE FIGURE
THICKNESS
0 in. - 1 in. Max.
13.18
1 in. - 4 in. Max.
13.19

Advertisement