Replacement routines
4.2

Replacing the operating panel

Ê Open the server and remove the front cover or the rack front cover as
described in the
Figure 2: Removing the operating panel module
Ê Press the two metal tongues of the EasyClick rails inward (1) until the locking
mechanism is released.
Ê Pull the operating panel module forward out of its mounting location (2) until
you can remove the I
operating panel board. Remove the three cables.
Ê Remove the operating panel module.
Ê Push the operating panel module halfway into the upper bay of the drive
cage.
2
Ê Connect the I
panel board (see the board layout on
Ê Now push the operating panel module fully into the upper bay of the drive
cage.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
TX300 S3
section "Preparation" on page
2
C cable, the ribbon cable and the USB cable from the
C cable, the ribbon cable and the USB cable to the operating
Service Supplement
Replacing the operating panel
17.
1
2
1
page
37).