Replacing The Idtemp Combo - Fujitsu PRIMERGY TX300 S3 Service Supplement Manual

Hide thumbs Also See for PRIMERGY TX300 S3:
Table of Contents

Advertisement

Replacing the IDTEMP combo

Ê Push the hard disk cage in its bay and fasten it with six screws on the front
side and with two screws on the rear side.
V
CAUTION!
Make sure not to damage the cables.
Ê Insert the intrusion switch with the two wires in its holder and fasten the
switch with two screws.
Ê Install the SAS/SATA backplane holder as described in
the SAS/SATA backplane" on page
Figure 13: Installing the hood guide
Ê Hook the hood guide into the right hand side. Push it down until it engages
on the left hand side (see circle).
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.7
Replacing the IDTEMP combo
This board includes two important system components:
– EEPROM for the chassis ID and ident number of the server
– temperature sensor for monitoring the environment temperature
The data for the EEPROM, and the current temperature values as well, are
transmitted to the system board via the connected I2C bus.
32
23.
Service Supplement
Replacement routines
section "Replacing
TX300 S3

Advertisement

Table of Contents
loading

Table of Contents