Communication interfaces
Table 18-1
Class
C
Recommended for SIMEAS R-PMU: 192.168.subnet.device (subnet: 1 to 254
and device: 1 to 254)
Table 18-2
Baud rate
Data bits
Stop bits
Parity
Table 18-3
Baud rate
Data bits
Stop bits
Parity
Supply voltage
Normal operation
Table 18-4
Voltage type
DC (low-voltage)
DC (high-voltage)
AC (50 Hz / 60 Hz)
Emergency operation with battery package:
Table 18-5
Rated direct voltage
Duration of emergency power operation
Useful power reserve
Temperature range
Digital Fault Recorder, SIMEAS R-PMU, Manual
E50417-H1076-C360-A5, Release 10.2012
LAN: Ethernet class C (recommended)
Range of network numbers
192.0.0.x to 223.255.255.x
COM 1 setting
Setting
9,600 bit/s to 115,200 bit/s
8
1
none
COM S setting
Setting
19,200 bit/s
8
1
none
Supply voltages
Rated voltages
DC 24 V / DC 48 V / DC 60 V
DC 110 V / DC 125 V / DC 220 V /
DC 250 V
AC 115 V / AC 230 V
Battery package (NiCd)
Rated capacity
Service life
18.1 Modules of the SIMEAS R-PMU
Subnet mask
255.255.255.0
Permissible range
DC 19.2 V to DC 72 V
DC 88 V to DC 300 V
AC 92 V to AC 276 V;
45 Hz to 65 Hz
Values
DC 12 V
1.2 Ah
at least 10 min
12 Wh
-20 °C to +70 °C
3 years (at an ambient temperature of 55 °C)
18