Traditional Logset Installation H34Df - Montigo HL34 Installation & Maintenance Manual

Indoor direct vent gas fireplace
Hide thumbs Also See for HL34:
Table of Contents

Advertisement

Traditional Logset Installation H34DF

AIR INLETS
PILOT
Figure 22. H34DF*'s Fireplace Base.
STEP 1: Remove the glass door as described in the previous
instruction.
STEP 2: Install Bottom Rear log
REAR LOG
NOTCH
STEP 3: Install Both front base logs, (Figure 28c) on the log stands
provided.
FRONT LEFT
BASE LOG
STEP 4: Place the top left log. A flat area is provided on the front
left log, and a notch in the Rear bottom log. Install the glass
door. If the flame does not appear satisfactory, double-check
the air inlet and exhaust outlet pipe to ensure that they are
unobstructed.
TOP LEFT
LOG
XG0228 - 021419
BASE
BASE
Figure 22.b
FRONT RIGHT
BASE LOG
Figure 22.c
Figure 22.d
STEP 5: Place the top right log as shown. A notch is provided on
the front right log, and a impression in the Rear bottom log.
STEP 6: Start the fireplace. If the flame appears satisfactory,
replace the glass door. If the flame does not appear satisfactory,
double-check the air inlet and exhaust outlet pipe to ensure that
they are unobstructed.
STEP 7: Place the Embers as shown. Arrange the ember chips on
top of the burner tray. Care should be taken when placing the
embers, as blocked burner ports may cause an incorrect flame
pattern, carbon deposits and delayed ignition. Also, the embers
must NEVER be placed in a way that obstructs any of the air inlet
ports, located at the rear of the burner.
EMBERS
Installation
TOP RIGHT
LOG
Figure 22.e
EMBERS
EMBERS
Figure 22.f
33

Hide quick links: