PERATION

Operation

Contact the factory, the factory representative or a local service company to perform maintenance and repairs
should the appliance malfunction.
If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been corrected.
In the event of main burner ignition failure, a 5 minute purge period must be observed prior
In the event you smell gas, shut down equipment at the main shut off valve and contact the
Gas Control Instructions
The units do not require "lighting" the pilot with a match.
A. Lighting
1. Open manual gas shut off valve.
2. Set thermostat to OFF, and kettle in fully upright position, turn power switch ON.
3. Set thermostat to maximum, initiating a 30 second pre-purge. Red "COOKING" pilot will come on, and after 30
seconds, the green "IGNITION" pilot will come on, lighting the main burners.
If after 36 seconds the burner fails to ignite or the "ignition light goes out, the system goes into Safety Lockout. De-
energize the system by setting the thermostat to "OFF" for five minutes and try again.
4. Set the thermostat to desired temperature setting. When temperature setting has been reached, the "IGNITION" pilot
will go off, turning off the burner. The unit will then cycle on and off to maintain set temperature.
When the kettle is tilted a safety switch will automatically turn off gas supply.
8
PAGE
OF 32
NOTICE
CAUTION
WARNING
to re-establishing ignition source.
WARNING
local gas company or gas supplier for service.
NOTICE
Unit is shipped with gas combination valve turned "on".
NOTICE
The kettle will not operate once it has been tilted.