Maintenance

Maintenance
Contact the factory, the factory representative or a local service company to perform maintenance and repairs.
Disconnect the power supply to the appliance before cleaning or servicing.
Daily
1. Wash exposed cleanable areas.
Monthly
1. Blower wheel inlet and motor air vent should be cleansed if an accumulation of dust or lint is obvious.
Twice a Year (minimum)
1. Have an authorized service person clean and adjust the unit for maximum performance.
2. The unit venting system should be examined and cleaned.
3. Grease the screw jack tilt mechanism via the lubricating nipple. Use Petro-Canada type OG-2 or equivalent.
Annually
1. Have an authorized service person inspect the screw jack assembly for wear. The screw must be replaced
immediately if the end play has reached 0.019" [0.5mm].