Overview of DFE Module Shutdown Procedure

The DFE modules installed in a Matrix E7,Matrix N1, Matrix N3, Matrix N5, or Matrix N7 
chassis are interdependent and operate under a single IP address as a single, distributed 
switch system (hardware, databases, and persistent storage). In this operating 
environment, the DFE module must shut down in an orderly fashion to ensure that the 
other modules in the system and other devices on the network are notified of the 
impending change. The device(s) can then make intelligent decisions and stabilize the 
network before the change is made; thereby increasing network availability.
You can shut down a DFE module in an operating system using the OFFLINE/RESET 
switch shown in Figure
Recommended shutdown procedure ("Recommended Shutdown Procedure Using 
OFFLINE/RESET Switch" on page 4‐8)
Last resort shutdown procedure (not recommended)
Procedure Using OFFLINE/RESET Switch" on page 4‐8) 
Figure 4-2

1 OFFLINE/RESET switch

Caution: Do not remove a DFE-Platinum module from an operating chassis system
before reading the following information and instructions.
Precaución: Antes de retirar los módulos DFE-Platinum del chasis en
funcionamiento, lea las siguientes instrucciones y la información suministrada.
4‐2. There are two procedures to shut down a DFE module.
OFFLINE/RESET Switch
Overview of DFE Module Shutdown Procedure
("Last Resort Shutdown 