Recommended Shutdown Procedure Using OFFLINE/RESET Switch

Recommended Shutdown Procedure Using OFFLINE/RESET
Switch
Before pulling a DFE module out of a chassis, 
press or tap on its OFFLINE/RESET switch for less than 1 second. 
Its CPU LED changes from solid green to blinking between green and amber, indicating 
that the DFE module is shutting down. At the end of the DFE module shutdown routine, 
the CPU LED changes to a 67%/33% sequence of amber/off, respectively, indicating the 
module is in a halt state. In this time it is safe to restart or remove the DFE module from 
the chassis.
When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60 
seconds from the time the CPU starts flashing amber/off until the time the device is 
automatically restarted.
Last Resort Shutdown Procedure Using OFFLINE/RESET
Switch
To reset a DFE module without it performing an orderly shutdown routine, 
press and hold the OFFLINE/RESET switch for approximately 6 seconds. 
Pulling any DFE module out of the chassis before it has been shut down is not 
recommended. The only safe time to pull a module out of the chassis is after the 
completion of a shutdown and the management LED is flashing amber/off.
4-8 Troubleshooting
Caution: Do not pull any DFE-Platinum module out of an operating chassis before it has
completed its shutdown routine.
Precaución: No retire los módulos DFE-Platinum del chasis en funcionamiento hasta
que no se haya terminado con la rutina de apagado.
Note: The only safe time to pull a DFE module out of the chassis is when the CPU LED is
blinking amber. Otherwise, system operation will be interrupted.
Caution: This method of shutting down a DFE-Platinum module is not recommended
except as a last resort, because all processes currently running on the module will be
interrupted resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos
DFE-Platinum. Recurra a él sólo como último recurso, puesto que interrumpe todos los
procesos del módulo en funcionamiento, lo que podría resultar pérdidas de frames.