Overview of DFE-Platinum Module Shutdown Procedure

DFE‐Platinum modules installed in a Matrix N3, Matrix N7, or Matrix E7 chassis are 
interdependent and operate under a single IP address as a single, distributed switch 
system (hardware, databases, and persistent storage). In this operating environment, the 
DFE‐Platinum module must shut down in an orderly fashion to ensure that the other 
modules in the system and other devices on the network are notified of the impending 
change. The device(s) can then make intelligent decisions and stabilize the network before 
the change is made; thereby increasing network availability.
You can shut down a DFE‐Platinum module in an operating system using the OFFLINE/
RESET switch shown in Figure
DFE‐Platinum module.
Recommended shutdown procedure (page 4‐8)
Last resort shutdown procedure (not recommended) (page 4‐8)
Figure 4-2

1 OFFLINE/RESET switch

Caution: Do not remove a DFE-Platinum module from an operating chassis system
before reading the following information and instructions.
Precaución: Antes de retirar los módulos DFE-Platinum del chasis en funcionamiento,
lea las siguientes instrucciones y la información suministrada.
OFFLINE/RESET Switch
Overview of DFE-Platinum Module Shutdown Procedure
4‐2. There are two procedures to shut down a 
DFE-Platinum Series Hardware Installation Guide 4-7