Calculating Collector Row Clearance Z; Fitting Collector Supports - Viessmann Vitosol-F Installation Instructions For Contractors

Flat-plate collector for installation on collector supports collector supports with fixed angle of inclination

Advertisement

Calculating collector row clearance z

When installing several collectors one behind the
other, maintain clearance z to prevent unwanted shad-
ing.
α
z
Fig. 6
z Collector row clearance
Collector angle of inclination
α
Angle of the sun
β
Collector angle of inclination
Flensburg
30°
45°
60°
Kassel
30°
45°
60°
Munich
30°
45°
60°

Fitting collector supports

Observe the maximum load and distance from the
edge of the roof for the on-site substructure to
DIN 1055.
Install the on-site substructure, e.g. steel beams, at
right angles to and horizontally level with the collec-
tor orientation.
Provide screws on site for securing the collector sup-
ports to the substructure.
8
α
β
α
Collector row clearance z in mm
Type SV
7630
9600
10890
6385
7840
8720
5595
6710
7350
Type SH
5715
4260
4830
2845
3480
3870
2485
2980
3260