Installation On Collector Supports - Viessmann Vitosol 200-T Installation Instructions Manual

Table of Contents

Advertisement

Pitched roof installation with roof hooks
90°
10.
Fig. 63
Note on step 9:
Use the centring groove on the back of the header
casing as a drilling guide.

Installation on collector supports

Prevent shading if several collectors are installed
behind each other. Maintain clearance z between
rows.
1. Determine the angle
(the shortest day of the year) at midday.
In Germany, this angle measures between 11.5°
(Flensburg) and 19.5° (Konstanz), subject to lati-
tude.
Example:
Würzburg is approximately located on latitude 50°
north. In the northern hemisphere, this value is
deducted from a fixed angle of 66.5°:
= 66.5°
50° = 16.5°
β
50
8.
9.
Ø9
of the sun on 21 December
β
(cont.)
7.
Continue with chapter "Hydraulic connections" (see
page 63).
2. To calculate dimension z:
h = 2241 mm
= 45°
α
= 16.5°
β