Operation Of The Hmi; Changing The Set Values; Setting The Motor Speed - Bosch EPS 610 Original Instructions Manual

Injection pump test bench
Table of Contents

Advertisement

en
18 | EPS 610 | Program description
Fig. 16:
Control buttons
5.2

Operation of the HMI

i
As a good practice, it is recommended to switch on
and switch off the EPS 610 twice before first opera-
tion.
Switch on the EPS 610.
 The HMI is powered on. Wait until the default
screen is displayed.
 A typical view of the default screen is depicted
below.
Fig. 17:
Example default screen
|
F 002 DG9 918
2017-10-16
The symbols on the HMI display are described in the
following table.
Display
Description
symbol
Indicator of RPM
left: actual RPM
right: target RPM
Direction of rotation of the drive motor
L = counter clockwise
R = clockwise
Stroke count
left: Remaining strokes,
right: Stroke count to be measured
Cursor
Tank temperature
left: actual temperature
right: target temperature
Inlet temperature
left: actual temperature
right: target temperature
Outlet temperature
left: actual temperature
right: target temperature
In the lower right area of the display, error mes-
sages are displayed or the status is shown brief-
ly
Tab. 4:
Description of the default screen symbols
1) In view to the shaft of the injection pump
i
Refer to the test specification of the pump and
change the parameters accordingly.
5.3

Changing the set values

i
The changes are saved and are available after switch-
ing the EPS 610 off and back on again.
i
Changes to the set value are only possible with a
switched on test oil pump.
5.3.1

Setting the motor speed

4. Press <RPM selection>.
 The cursor appears on the display.
5. Set desired rotational speed with <o> or <u> or with
the numerical keys.
6. Press <Enter>.
"
The motor speed value is stored and displayed.
Bosch Limited