Decommissioning; Temporary Shutdown; Change Of Location; Disposal And Scrapping - Bosch EPS 610 Original Instructions Manual

Injection pump test bench
Table of Contents

Advertisement

en
30 | EPS 610 | Decommissioning
9.

Decommissioning

9.1

Temporary shutdown

In the event of lengthy periods of non-use:
Disconnect the EPS 610 from the mains.
Drain the test oil from the test oil tank.
Shut off and disconnect the water supply.
Plug all the hoses.
Apply anti-corrosive material to machined surfaces.
Cover the EPS 610.
9.2

Change of location

If the EPS 610 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
The EPS 610 is only ever to be transported in the
original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
Contact customer service to shift the EPS 610 from
one place to another.
During transportation, fit transportation safeguards.
Drain the test oil from the test oil tank.
Ensure that there are no loose parts.
Apply anti-corrosive to the machined surfaces of the
EPS 610 before transportation.
Secure the MGT.
|
F 002 DG9 918
2017-10-16
9.3

Disposal and scrapping

9.3.1

Substances hazardous to water

!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
i
Test oil as per ISO 4113 is classified under used oil
collection category 1. In category 1, the used oil
must not contain any foreign substances such as
used oils of a different category, gasoline or diesel.
The corresponding refuse code number can be taken
from the safety data sheet of the test oil.
9.3.2

EPS 610 and accessories

1. Disconnect the EPS 610 from the mains and detach
the power cord.
2. Dismantle the EPS 610 and sort out and dispose of
the different materials in accordance with the ap-
plicable regulations.
Dispose of used electrical and electronic devices, in-
cluding cables, accessories and batteries, separately
from household waste.
Make use of the local return and collection systems
for disposal.
Proper disposal of the EPS 610 prevents environ-
mental pollution and possible health hazards.
Bosch Limited

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents