7.2

Drive error messages

Error code
1000
A phase is missing on the supply side, or the mains volt-
age imbalance is too high.
1001
There is no communication to the frequency converter.
1002
There is a short circuit in the motor or on the motor ter-
minals.
1003
Motor has not been connected to the output of the fre-
quency converter.
1004
DC overvoltage
1005
The frequency converter is overloaded by more than
100%.
1006
The inverter peak current (approximately 200% of the rat-
ed current) is exceeded.
1007
The intermediate circuit voltage is higher than the over-
voltage limit of the control system. The frequency con-
verter is still live.
1008
Torque Limit
1009
Brake Resistor Short circuited
1010
Motor is too hot since it is loaded more than 100%.
1011
Braking power is higher than 100%.
1012
Short circuit or brake resistor overheat.
1013
There is a discharge from the output phases to earth, ei-
ther in the cable between the frequency converter and
the motor or in the motor itself.
1014
Internal Fan Fault
1015
The intermediate circuit voltage is below the under volt-
age limit of the control system.
1016
The intermediate circuit voltage is below the under volt-
age limit of the control system.
1020
A fitted option is not handled by the present control
board
1021
Signal on terminal 53 or 54 is less than 50%
1022
Brake Resistor open circuit
1023
Motor phase U is missing.
1024
Motor phase V is missing.
1025
Motor phase W is missing.
Bosch Limited
Causes
Operation | EPS 610 | 25
Remedy
R Check the incoming power supply at the frequency
drive.
R Contact customer service.
R Check if the frequency drive settings are as per the
electrical wiring diagram.
R Contact customer service.
R Check if the connections from the motor to the drive
are as per the electrical wiring diagram.
R Contact customer service.
R Check if the connections from the motor to the drive
are as per the electrical wiring diagram.
R Contact customer service.
R Check the parameter setting, it should be as per the
electrical circuit diagram.
R Switch off the EPS 610 and switch on.
R If the error persists, contact customer service to re-
place the frequency drive.
R Check the condition of the fuel injection pump under
test.
R Contact customer service.
R Contact customer service.
The warning will last approximately 8-12 seconds. Then,
the frequency converter trips and issues an alarm.
R Check the incoming connection, braking resistor and
the fuel injection pump under test.
R Contact customer service.
R Check the condition of the fuel injection pump under
test.
Contact customer service.
R Check the condition of the fuel injection pump under
test.
R Check if the coupling can freely transfer the torque.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
Contact customer service.
F 002 DG9 918
en
|
2017-10-16