Maintenance; Cleaning; Spare And Wearing Parts; Servicing - Bosch EPS 610 Original Instructions Manual

Injection pump test bench
Table of Contents

Advertisement

en
26 | EPS 610 | Maintenance
8.

Maintenance

!
Work on electrical and hydraulic equipment is only to
be performed by persons with sufficient knowledge
and experience of electrical and hydraulic systems.
8.1

Cleaning

!
Do not use any abrasive cleaning agents or rough
cleaning cloths.
Only use soft cleaning cloths and neutral cleaning
agents to clean the EPS 610.
8.2

Spare and wearing parts

Designation
Hose for calibrating oil supply
Suction strainer
Filter insert
Flexible coupling
8.3.1

Maintenance intervals

Sl. no.
8.1
Cleaning of EPS 610
-
Check the measuring glasses visually for any defects. In case of defects, con-
tact customer service to order spare measuring glasses.
8.3.2
Drain the used test oil from the top tray
8.3.3
Cleaning of strainer in MGT
-
Check the nozzle opening pressure pursuant to the regulations. If required,
adjust the
pressure.
-
Interchange the nozzle holders and pressure lines and compare the flow
rates. The flow rates must be
-
Check if the sealing cones and bores of the pressure lines are perfectly func-
tional. Else, replace with new pressure lines.
-
Contact customer service to check pressure gauges.
-
Contact customer service to check accuracy of the temperature unit, mea-
suring and control devices.
8.3.4
Change the test oil in test oil tank. Check for water leakage from the heat ex-
changer into the tank before refilling oil.
8.3.5
Clean and rinse the test oil tank and suction filter. If the suction strainer is
contaminated even after rinsing, contact customer
8.3.6
Check the drive coupling.
8.3.7
Clean the suction strainer in test oil tank
-
Tightening torque for fixtures and pumps: Check and tighten if required. Re-
fer chapter 10.3 for information on torque values.
Tab. 5:
Maintenance intervals
|
F 002 DG9 918
2017-10-16
Order no.
F 002 81N F07
F 002 81N F75
F 002 DG1 9F2
1 686 401 026
Maintenance task
equal.
service.
8.3

Servicing

The EPS 610 requires proper maintenance at regular
intervals. The maintenance intervals are recommended
under the assumption that the EPS 610 is operated for
8 hours at a vehicle service center. The intervals have to
be reduced if the operating time is extended.
Wear safety goggles.
Wear safety gloves.
Wear slip resistant safety shoes.
Wear ear mufflers.
i
Do not perform any other maintenance tasks other
than those described in this chapter.
!
Quit the voltage supply during the maintenance if
possible.
Daily
Weekly
x
x
x
x
After
During
testing
inspec-
Yearly
200
tion
pumps
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Bosch Limited

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents