8.8 Ozonator Not Working (Optional)

Diagnostic Tools: Clamp-on Ammeter, Voltmeter
Suggested Spare Parts: Ozonator, Circuit Board, Control Panel
Standard Troubleshooting Approach
Refer to pages 43-46 for testing points.
Turn power to hot tub off and on.
Wait approximately two minutes
for filter cycle to begin and turn
on the circulation pump and
ozonator.
DO NOT press either JETS
button at this time or ozonator
will shut off! Is filter cycle 1
running?
Yes
Is 120 VAC* or 240 VAC present
at circuit board ozone outputs?
Test points 16 and 17, See pages
43-46.
*Convertible J-315 and J-325
models only.
Yes
Is there a faint buzzing sound
coming from the ozonator's
internal high voltage arching
chamber? Or is there current
draw from the ozonator
(≈ 0.1 Amp)? Check with clamp-
on ammeter.
Yes
A faint buzzing sound and/or
current draw is proof that the
ozonator is working.
Read steps outlined above to
ensure customer understands
ozone logic.
No
Turn power off, plug
in spare control panel,
then turn power on. Wait
approximately 2 minutes
for filter cycle to begin. Is
filter cycle running?
Yes
Replace control panel.
No
Replace circuit board.
No
Replace ozonator.
No
Replace circuit board
DANGER: Electrical Shock Hazard Exists!
High Voltage Present on Circuit Board. Use
Extreme Caution while Servicing Circuit Board.